The imaging performance of a recently developed digital flat-panel detector system was compared with conventional screen-film imaging in an observer preference study. In total, 34 image pairs of various regions of the skeleton were obtained in 24 patients; 30 image pairs were included in the study. The conventional images were acquired with 250- and 400-speed screen-film combinations, using the standard technique of our department. Within hours, the digital images were obtained using identical exposure parameters. The digital system employed a large-area (43x43 cm) flat-panel detector based on amorphous silicon (Trixell Pixium 4600), integrated in a Bucky table. Six radiologists independently evaluated the image pairs with respect to image latitude, soft tissue rendition, rendition of the periosteal and enosteal border of cortical bone, rendition of cancellous bone and the visibility of potentially present pathological changes, using a subjective five-point scale. The digital images were rated significantly (p=0.001) better than the screen-film images with respect to soft tissue rendition and image latitude. Also the rendition of the cancellous bone and the periosteal and enosteal border of the cortical bone was rated significantly (p=0.05) better for the flat-panel detector. The visibility of pathological lesions was equivalent; only large-area sclerotic lesions (n=2) were seen superiorly on screen-film images. The new digital flat-panel detector based on amorphous silicon appears to be at least equivalent to conventional screen-film combinations for skeletal examinations, and in most respects even superior.
机译:在观察者偏好研究中,将最近开发的数字平板探测器系统的成像性能与传统的屏幕胶片成像进行了比较。总共有24例患者获得了34个骨骼各区域的图像对。研究中包括30对图像。常规图像是使用我们部门的标准技术通过250倍速和400倍速电影胶片组合获得的。在数小时内,使用相同的曝光参数获得了数字图像。该数字系统采用了基于非晶硅(Trixell Pixium 4600)的大面积(43x43厘米)平板探测器,并集成在Bucky桌子中。六位放射科医生使用主观五点量表,分别根据图像的纬度,软组织翻译,皮质骨的骨膜和葡萄膜边界的翻译,松质骨的翻译以及可能存在的病理变化的可见性,独立评估了图像对。就软组织再现和图像纬度而言,数字图像的评分显着优于屏幕胶片图像(p = 0.001)。对于平板检测器,松质骨以及皮质骨的骨膜和骨膜边界的移出也得到了更好的评价(p = 0.05)。病理病变的可见度是相等的;在屏幕胶片图像上仅能看到较大面积的硬化性病变(n = 2)。基于非晶硅的新型数字平板探测器似乎至少等同于用于骨骼检查的常规屏幕胶片组合,并且在大多数方面甚至更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号