首页> 外文期刊>European radiology >Quantification of intracranial internal carotid artery calcification on brain unenhanced CT: Evaluation of its feasibility and assessment of the reliability of visual grading scales
【24h】

Quantification of intracranial internal carotid artery calcification on brain unenhanced CT: Evaluation of its feasibility and assessment of the reliability of visual grading scales

机译:颅内颈内动脉钙化在未增强脑CT上的量化:其可行性评估和视觉分级量表的可靠性评估

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives: Previous studies have evaluated intracranial internal carotid artery calcifications (ICACs) qualitatively using different visual grading scales, which could lead to inconsistent results. The purpose of this study was to evaluate the feasibility of ICAC volume measurement and to correlate the volume with visual grading scales. Methods: We included 49 patients (50years) who underwent unenhanced cranial CT. Two observers evaluated four visual grading scales and measured ICAC volumes semi-automatically, and interobserver agreements were assessed. Differences in ICAC volume between visual grades of each scale were tested. The relationship between the visual grading and volume was assessed. Results: Interobserver agreements ranged from 0.841 to 0.901 for visual grading and 0.997 for volume measurement. Mean volumes were not significantly different between the visual grades (P 0.05) except when comparing grade 4 with the other grades. The grades of each visual grading correlated well with ICAC volumes (Spearman's ρ = 0.849-0.881, P 0.001). The relationship between the visual grades and volume was described by a quadratic model (R 2, 0.31-0.50, P 0.01). Conclusions: ICAC volume measurement is feasible and reproducible, whereas visual grades poorly reflect the actual volume; therefore, volume measurement may be warranted for future research. Key Points: ? Computed tomography provides unique information about vascular calcification. ? Volume measurement of intracranial carotid artery calcification is feasible and reproducible. ? Visual grades poorly reflect the volume of intracranial carotid artery calcification. ? Quantification of intracranial carotid artery calcification is warranted for future research.
机译:目的:以前的研究使用不同的视觉分级量表定性评估了颅内颈内动脉钙化(ICAC),这可能导致结果不一致。这项研究的目的是评估廉政公署的体积测量的可行性,并将体积与视觉分级尺度相关联。方法:我们纳入了49例(> 50岁)接受了不增强颅CT扫描的患者。两名观察员评估了四个视觉等级量表,并半自动地测量了ICAC的体积,并评估了观察员之间的协议。测试了每个量表的视觉等级之间的ICAC体积差异。评估视觉等级和体积之间的关系。结果:观察者之间的一致度从视觉等级到0.841到0.901,从体积测量到0.997。视觉等级之间的平均体积没有显着差异(P> 0.05),除了将等级4与其他等级进行比较时。每个视觉分级的等级与廉政公署的数量有很好的相关性(斯皮尔曼的ρ= 0.849-0.881,P <0.001)。视觉等级和体积之间的关系由二次模型描述(R 2,0.31-0.50,P <0.01)。结论:廉政公署的体积测量是可行和可重复的,而视觉等级却不能很好地反映实际体积。因此,可能需要进行体积测量以备将来研究。关键点: ?计算机断层扫描可提供有关血管钙化的独特信息。 ?颅内颈动脉钙化的体积测量是可行且可重复的。 ?视觉等级不能很好地反映颅内颈动脉钙化的量。 ?颅内颈动脉钙化的量化值得进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号