...
首页> 外文期刊>European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society >Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.
【24h】

Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.

机译:记录腋窝胸壁电极触发的EMG阈值:一种精确定位上胸(T2-T6)椎弓根螺钉的新改良技术。

获取原文
获取原文并翻译 | 示例
           

摘要

This study was aimed at evaluating the sensitivity and safety of a new technique to record triggered EMG thresholds from axillary chest wall electrodes when inserting pedicle screws in the upper thoracic spine (T2-T6). A total of 248 (36.6%) of a total of 677 thoracic screws were placed at the T2-T6 levels in 92 patients with adolescent idiopathic scoliosis. A single electrode placed at the axillary midline was able to record potentials during surgery from all T2-T6 myotomes at each side. Eleven screws were removed during surgery because of malposition according to intraoperative fluoroscopic views. Screw position was evaluated after surgery in the remaining 237 screws using a CT scan. Malposition was detected in 35 pedicle screws (14.7%). Pedicle medial cortex was breached in 24 (10.1%). Six screws (2.5%) were located inside the spinal canal. Mean EMG threshold was 24.44 +/- 11.30 mA in well-positioned screws, 17.98 +/- 8.24 mA (p < 0.01) in screws violating the pedicle medial cortex, and 10.38 +/- 3.33 mA (p < 0.005) in screws located inside the spinal canal. Below a threshold of 12 mA, 33.4% of the screws (10/30) were malpositioned. Furthermore, 36% of the pedicle screws with t-EMG stimulation thresholds within the range 6-12 mA were malpositioned. In conclusion, assessment of upper thoracic pedicle screw placement by recording tEMG at a single axillary electrode was highly reliable. Thresholds below 12 mA should alert surgeons to suspect screw malposition. This technique simplifies tEMG potential recording to facilitate safe placement of pedicle screws at upper thoracic levels.
机译:这项研究的目的是评估一种新技术的敏感性和安全性,该技术可在将椎弓根螺钉插入胸椎上段(T2-T6)时记录腋下胸壁电极触发的EMG阈值。在92例青少年特发性脊柱侧弯患者中,总共677枚胸螺钉中的248枚(36.6%)处于T2-T6水平。放置在腋中线的单个电极能够记录手术过程中每一侧所有T2-T6肌电图的电位。根据术中透视检查,由于位置不正确,在手术过程中卸下了11个螺钉。手术后,使用CT扫描评估剩余237个螺钉中的螺钉位置。在35个椎弓根螺钉中发现位置不正确(14.7%)。椎弓根内侧皮层破裂24例(占10.1%)。六个螺钉(2.5%)位于椎管内。位置良好的螺钉的平均EMG阈值为24.44 +/- 11.30 mA,侵犯椎弓根内侧皮质的螺钉的平均EMG阈值为17.98 +/- 8.24 mA(p <0.01),而位于螺钉的螺钉为10.38 +/- 3.33 mA(p <0.005)在椎管内。低于12 mA的阈值时,错位了33.4%的螺钉(10/30)。此外,t-EMG刺激阈值在6-12 mA范围内的椎弓根螺钉位置错误。总之,通过在单个腋窝电极处记录tEMG来评估上胸椎椎弓根螺钉的放置高度可靠。低于12 mA的阈值应提醒外科医生怀疑螺钉位置不正确。这项技术简化了tEMG电位记录,有助于安全地将椎弓根螺钉放置在胸廓上方。

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号