首页> 外文期刊>European Journal of Pharmacology: An International Journal >Simultaneous measurement of mechanical responses and transepithelial potential difference and resistance, in guinea-pig isolated, perfused trachea using a novel apparatus: pharmacological characterization.
【24h】

Simultaneous measurement of mechanical responses and transepithelial potential difference and resistance, in guinea-pig isolated, perfused trachea using a novel apparatus: pharmacological characterization.

机译:使用一种新型仪器,在豚鼠分离的灌注气管中,同时测量机械反应,跨上皮电位差和抵抗力:药理学表征。

获取原文
获取原文并翻译 | 示例
       

摘要

The isolated, perfused trachea preparation has been used to compare reactivity of the intact airway in response to differential exposure of the mucosal (intraluminal) and serosal (extraluminal) surfaces to contractile and relaxant agonists and other agents, and to gain insight into the modulatory role of the epithelium and the pathways involved. The apparatus has also been configured for simultaneous measurement of transepithelial potential difference and changes in tracheal diameter, thereby providing parallel observations of epithelial and smooth muscle function and reactivity to drugs. The transepithelial potential difference is a product of transepithelial resistance and short circuit current, and the present study describes a novel isolated, perfused tracheal apparatus which allows simultaneous measurement of transepithelial potential difference, transepithelial resistance and mechanical responses of the smooth muscle. The apparatus was validated using well-known ion transport inhibitors [intraluminal amiloride and 5-nitro-2-(3-phenylpropyl-amino) benzoic acid (NPPB), extraluminal ouabain and bumetanide], bronchoactive agonists (extraluminal methacholine, histamine and terbutaline), and osmolytes (intraluminal d-mannitol and NaCl) to induce epithelium-derived relaxing factor-mediated relaxations. This apparatus will facilitate investigation of interactions between the epithelium and smooth muscle in airways that retain their in situ structure, and signaling mechanisms potentially involved in the regulation of airway smooth muscle tone.
机译:分离的灌注气管制剂已用于比较完整气道的反应性,以响应粘膜(管腔内)和浆膜(管腔外)表面对收缩性和松弛性激动剂及其他药物的不同暴露,并深入了解其调节作用上皮及其相关的通路。该设备还配置用于同时测量跨上皮电位差和气管直径的变化,从而提供上皮和平滑肌功能以及对药物反应性的平行观察。跨上皮电位差是跨上皮电阻和短路电流的乘积,本研究描述了一种新型的隔离,灌注气管仪器,该仪器可同时测量跨上皮电位差,跨上皮电阻和平滑肌的机械反应。使用已知的离子迁移抑制剂[腔内阿米洛利和5-硝基-2-(3-苯基丙基-氨基)苯甲酸(NPPB),腔外哇巴因和布美他尼],支气管活性激动剂(腔外乙酰甲胆碱,组胺和特布他林)对仪器进行了验证和渗透液(腔内d-甘露醇和NaCl)诱导上皮来源的松弛因子介导的松弛。该装置将有助于调查上皮和气道中保持其原位结构的平滑肌之间的相互作用,以及可能参与调节气道平滑肌音调的信号传导机制。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号