首页> 外文期刊>European Journal of Radiology >Determination of the optimal energy level in spectral CT imaging for displaying abdominal vessels in pediatric patients
【24h】

Determination of the optimal energy level in spectral CT imaging for displaying abdominal vessels in pediatric patients

机译:频谱CT成像中显示小儿腹部血管的最佳能量水平的确定

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose To determine the optimal energy level in contrast-enhanced spectral CT imaging for displaying abdominal vessels in pediatric patients. Materials and methods This retrospective study was institutional review board approved. 15 children (8 males and 7 females, age range, 6-15 years, mean age 10.1 ± 3.1 years) underwent contrast-enhanced spectral CT imaging for diagnosing solid tumors in abdomen and pelvic areas were included. A single contrast-enhanced scan was performed using a dual energy spectral CT mode with a new split contrast injection scheme (iodixanol at 1-1.5 ml/kg dose. 2/3 first, 1/3 at 7-15 s after the first injection). 101 sets of monochromatic images with photon energies of 40-140 keV with 1 keV interval were reconstructed. Contrast-noise-ratio (CNR) for hepatic portal or vein were generated and compared at every energy level to determine the optimal energy level to maximize CNR. 2 board-certified radiologists interpreted the selected image sets independently for image quality scores. Results CT values and CNR for the vessels increased as photon energy decreased from 140 to 40 keV: (CT value: 48.29-570.12 HU, CNR: 0.08-14.90) in the abdominal aorta, (58.48-369.73 HU, 0.64-5.87) in the inferior vena cava, and (58.48-369.73 HU, 0.06-6.96) in the portal vein. Monochromatic images at 40-50 keV (average 42.0 ± 4.67 keV) could display vessels above three levels clearly, and with excellent image quality scores of 3.17 ± 0.58 (of 4) (k = 0.50). The CNR values at the optimal energy level were significantly higher than those at 70 keV, an average energy corresponding to the conventional 120 kVp for abdominal CT imaging. Conclusion Spectral CT imaging provides a set of monochromatic images to optimize image quality and enhance vascular visibility, especially in the hepatic portal and vein systems. The best CNR for displaying abdominal vessels in children was obtained at 42 keV photon energy level.
机译:目的为了确定在造影剂增强型CT成像中显示儿科患者腹部血管的最佳能量水平。材料和方法这项回顾性研究获得了机构审查委员会的批准。包括15例儿童(男8例,女7例,年龄范围6-15岁,平均年龄10.1±3.1岁),接受了造影剂CT增强成像检查,以诊断腹部和骨盆区域的实体瘤。使用双能谱CT模式和新的拆分对比注射方案(碘克沙醇,剂量为1-1.5 ml / kg,先进行2/3,初次注射后7-15 s,进行1/3)进行单次增强扫描)。重建了光子能量为40-140 keV,间隔为1 keV的101组单色图像。生成了肝门或静脉的对比噪声比(CNR),并在每种能量水平下进行比较,以确定使CNR最大化的最佳能量水平。 2名获得董事会认证的放射科医生单独对所选图像集进行解释,以获取图像质量得分。结果腹部主动脉中的光子能量从140 keV降低至40 keV时血管的CT值和CNR升高:(CT值:48.29-570.12 HU,CNR:0.08-14.90),在腹部主动脉中(58.48-369.73 HU,0.64-5.87)下腔静脉和(58.48-369.73 HU,0.06-6.96)在门静脉中。 40-50 keV(平均42.0±4.67 keV)下的单色图像可以清晰地显示三个级别以上的血管,并且图像质量得分为3.17±0.58(4个)(k = 0.50)。最佳能量水平下的CNR值明显高于70 keV时的CNR值,其平均能量相当于用于腹部CT成像的常规120 kVp。结论光谱CT成像可提供一组单色图像,以优化图像质量并增强血管可见性,尤其是在肝门和静脉系统中。在42 keV光子能级下获得了显示儿童腹部血管的最佳CNR。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号