首页> 外文期刊>European journal of applied physiology >Reliability of a 5 x 6-s maximal cycling repeated-sprint test in trained female team-sport athletes.
【24h】

Reliability of a 5 x 6-s maximal cycling repeated-sprint test in trained female team-sport athletes.

机译:在训练有素的女子团体运动运动员中进行5 x 6-s最大循环重复冲刺测试的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

The present study examined the reliability of work and power measures during a 5 x 6-s cycle ergometer test of repeated-sprint ability. Nine, well-trained, female soccer players performed five, 5 x 6-s repeated-sprint tests on a front-access cycle ergometer on separate days. Sprints were separated by 24 s of active recovery. Absolute measures of total work done (W (tot)), total peak power (PP(tot)), work done during sprint 1 (W (1)) and peak power output during sprint 1 (PP(1)) were recorded. Decrement scores in work done (W (dec)) and peak power output (PP(dec)), and fatigue indices for work done (FI( W )) and peak power (FI( P )), were calculated. Significant improvements in all of the work and power measures were observed between trial 1 and subsequent trials (P < 0.05), but no significant differences were identified between trials 2, 3, 4 and 5. The same was true for increases in the decrement scores. The coefficient of variation (CV) was established to reflect within-subject reproducibility for each variable. The CV was significantly improved by the third trial for work done (W (tot) CV: trials 1-2 = 5.5%; trials 3-4 = 2.8%), peak power (PP(tot) CV: trials 1-2 = 5.1%; trials 3-4 = 2.7%) and performance decrement scores (P < 0.05). The standard error of measurement (SEM) and intraclass correlation coefficient (ICC) were also calculated for each variable and expressed within 95% confidence intervals. It was concluded that two familiarisation trials are optimal for collecting reliable data from a 5 x 6-s repeated-sprint cycling test. Furthermore, due to the large variation around performance decrement it was suggested that decrement scores ought to be interpreted with caution.
机译:本研究在重复冲刺能力的5 x 6 s周期测力计测试中检查了工作和功率措施的可靠性。九名训练有素的女子足球运动员在分开的几天里在前轮自行车测功机上进行了五次,5 x 6 s重复冲刺测试。短跑间隔24秒钟进行主动恢复。记录完成的总功(W(tot)),总的峰值功率(PP(tot)),在sprint 1期间完成的功(W(1))和在sprint 1期间输出的峰值功率(PP(1))的绝对度量。计算完成工作的减量分数(W(dec))和峰值功率输出(PP(dec)),以及完成工作的疲劳指数(FI(W))和峰值功率(FI(P))。在试验1和后续试验之间,观察到所有工作和功率测量指标都有显着改善(P <0.05),但是在试验2、3、4和5之间没有发现显着差异。减少得分的增加也是如此。 。建立变异系数(CV)以反映每个变量的受试者内部可重复性。对于完成的工作,第三次试验显着提高了CV(W(tot)CV:试验1-2 = 5.5%;试验3-4 = 2.8%),峰值功率(PP(tot)CV:试验1-2 = 5.1%;试验3-4 = 2.7%)和表现递减得分(P <0.05)。还为每个变量计算了标准测量误差(SEM)和组内相关系数(ICC),并在95%置信区间内表示。结论是,两次熟悉试验对于从5 x 6-s重复冲刺循环测试中收集可靠数据是最佳的。此外,由于性能下降的差异很大,因此建议对下降分数进行谨慎解释。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号