Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study.

机译:使用校准体模对异碘苄基胍心脏与纵隔的比例进行标准化:校正对正常数据库和多中心研究的影响。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study was performed to demonstrate that the results obtained with a calibration phantom could be used as a tool for standardizing measurement of heart to mediastinum (H/M) ratio in cardiac metaiodobenzylguanidine (MIBG) imaging.Images of the phantom containing (123)I-MIBG were acquired on the cameras in 10 hospitals (11 camera types) to determine the relationship between H/M ratios using different collimators: low-energy (LE) and medium-energy (ME)/low-medium-energy (LME) collimators. The effect of standardization on the ME-comparable H/M ratio was examined in two settings: a Japanese standard MIBG database (n = 62) and multicentre studies (n = 49). In a multicentre study, probable Alzheimer's disease (AD, n = 18) and probable dementia with Lewy bodies (DLB, n = 31) were studied and standardized by the calibration phantom method.Linear regression equations between LE and ME collimators were obtained for the phantom study in all institutions. When the H/M ratio with an LE collimator was corrected based upon the calibration phantom, the corrected values were comparable to those obtained using ME collimators. The standard database also exhibited a normal distribution after standardization as determined by skewness and goodness-of-fit test. A mixture of the populations by LE and ME collimators showed significant separation of AD and DLB groups (F ratio = 24.9 for the late H/M), but the corrected values resulted in higher F ratios for both early and late H/M (F ratio = 34.9 for the late H/M).Standardization of H/M ratios by the heart-chest calibration phantom method is feasible among different collimator types. This method could be practically used for multicentre comparison of H/M ratios.
机译:进行这项研究是为了证明用校准体模获得的结果可以用作标准化测量心脏异碘苄基胍(MIBG)成像中心脏与纵隔(H / M)比率的工具。包含(123)I的体模图像-在10家医院的摄像机(11种摄像机类型)上获取了MIBG,以确定使用不同的准直仪的H / M比率之间的关系:低能量(LE)和中能量(ME)/中低能量(LME)准直器。在两个设置中检查了标准化对ME可比的H / M比率的影响:日本标准MIBG数据库(n = 62)和多中心研究(n = 49)。在一项多中心研究中,研究了可能的阿尔茨海默氏病(AD,n = 18)和可能患有路易小体的痴呆症(DLB,n = 31),并通过校准幻影法进行了标准化,获得了LE和ME准直仪之间的线性回归方程。所有机构的幻像研究。当根据校准体模校正LE准直仪的H / M比时,校正后的值与使用ME准直仪获得的值相当。通过偏度和拟合优度检验确定,标准数据库在标准化后也显示正态分布。 LE和ME准直仪的混合种群显示AD和DLB组显着分离(晚期H / M的F比= 24.9),但校正后的值导致早期H / M和晚期H / M的F比更高(F晚期H / M的H / M比率= 34.9)。通过心胸校准体模法对H / M比率进行标准化在不同类型的准直仪中都是可行的。该方法可实际用于H / M比值的多中心比较。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号