Multielemental analysis of soils by atomic emission spectroscopy using an arc argon two-jet plasmatron

机译:电弧氩两射等离子体等离子体原子发射光谱法对土壤进行多元素分析

获取原文
获取原文并翻译 | 示例
       

摘要

A procedure is presented for the simultaneous determination of total trace elements (Pb, Bi, Cr, Ni, Sn, Be, Co, Ga, Mo, Nb, Se, Y, Yb, La, Ce, Mn, Ti, Zr, V, Zn, Cu, Ba, and Sr) in solid soil samples by atomic emission spectroscopy using an arc argon two-jet plasmatron as the source of spectrum excitation. The reliable stability of plasma jet, the low detection limits, the low effect of sample composition on analytical results, and the selection of optimal regime for the functioning of the generator and registration of spectra permitted the simultaneous determination of 23 elements from the same portion. The detection limit was n X 10~(-4)-n X 10~(-7) percent; the variance was 4-9 percent. The systematic error was insignificant.
机译:提出了一种同时测定总痕量元素(Pb,Bi,Cr,Ni,Sn,Be,Co,Ga,Mo,Nb,Se,Y,Yb,La,Ce,Mn,Ti,Zr,V原子发射光谱法,使用电弧氩气两射流等离子加速器作为光谱激发源,对固体土壤样品中的,,,,,等离子体射流的可靠稳定性,低检出限,样品成分对分析结果的影响小以及为发生器功能和光谱配准选择最佳方案的选择允许同时测定同一部分中的23种元素。检出限为n X 10〜(-4)-n X 10〜(-7)%。方差为4-9%。系统错误微不足道。