首页> 外文期刊>Environmental Science and Pollution Research >Rapid metal extractability tests from polluted mining soils by ultrasound probe sonication and microwave-assisted extraction systems
【24h】

Rapid metal extractability tests from polluted mining soils by ultrasound probe sonication and microwave-assisted extraction systems

机译:通过超声探头超声处理和微波辅助提取系统从污染的采矿土壤中快速进行金属提取能力测试

获取原文
获取原文并翻译 | 示例
           

摘要

Ultrasonic probe sonication (UPS) and microwave-assisted extraction (MAE) were used for rapid single extraction of Cd, Cr, Cu, Ni, Pb, and Zn from soils polluted by former mining activities (Mnica Mine, Bustarviejo, NW Madrid, Spain), using 0.01 mol L-1 calcium chloride (CaCl2), 0.43 mol L-1 acetic acid (CH3COOH), and 0.05 mol L-1 ethylenediaminetetraacetic acid (EDTA) at pH 7 as extracting agents. The optimum extraction conditions by UPS consisted of an extraction time of 2 min for both CaCl2 and EDTA extractions and 15 min for CH3COOH extraction, at 30% ultrasound (US) amplitude, whereas in the case of MAE, they consisted of 5 min at 50 A degrees C for both CaCl2 and EDTA extractions and 15 min at 120 A degrees C for CH3COOH extraction. Extractable concentrations were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The proposed methods were compared with a reduced version of the corresponding single extraction procedures proposed by the Standards, Measurements and Testing Programme (SM&T). The results obtained showed a great variability on extraction percentages, depending on the metal, the total concentration level and the soil sample, reaching high values in some areas. However, the correlation analysis showed that total concentration is the most relevant factor for element extractability in these soil samples. From the results obtained, the application of the accelerated extraction procedures, such as MAE and UPS, could be considered a useful approach to evaluate rapidly the extractability of the metals studied.
机译:超声探针超声(UPS)和微波辅助萃取(MAE)用于从以前的采矿活动(Mnica矿,Bustarviejo,西北马德里,西班牙)污染的土壤中快速单次萃取Cd,Cr,Cu,Ni,Pb和Zn ),使用0.01 mol L-1氯化钙(CaCl2),0.43 mol L-1乙酸(CH3COOH)和0.05 mol L-1乙二胺四乙酸(EDTA)作为萃取剂。 UPS的最佳萃取条件包括:在30%超声(美国)振幅下,CaCl2和EDTA萃取的萃取时间均为2分钟,CH3COOH萃取的萃取时间为15分钟,而在MAE情况下,萃取时间为50分钟的5分钟。 CaCl2和EDTA萃取温度均为摄氏度,CH3COOH萃取温度为120 A摄氏15分钟。可提取浓度通过电感耦合等离子体原子发射光谱法(ICP-AES)确定。将提议的方法与标准,测量和测试计划(SM&T)提议的相应单一萃取程序的简化版本进行了比较。所获得的结果表明,取决于金属,总浓度水平和土壤样品,提取百分比的变化很大,在某些地区达到很高的值。然而,相关分析表明,总浓度是这些土壤样品中元素提取能力的最相关因素。从获得的结果来看,加速萃取程序(如MAE和UPS)的应用可以被认为是一种快速评估所研究金属的可萃取性的有用方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号