Failure analysis of cupronickel condenser tubes of a crude distillation unit of a petrochemical refinery has been conducted. Condenser tubes carrying sea water were found to undergo premature failure which was preceded by extensive overall thinning, formation of shallow channels, pits, etc., and greyish-black internal deposits in one of the units. In the other unit, the failure of tubes was noticed without any significant overall thinning and in the presence of adherent, hard and black-brown deposits. The studies indicated that the increased velocity of sea water as well as the deficiency of iron in the alloy had resulted in failure in one case whereas relatively low velocity of water associated with deposition of sludge and bio-fouling were the causes of failure in the other case. The failure of tubes could be controlled by maintaining the water velocity within a specified range, flushing the tubes with clean water, use of and fouling paints, selecting a more appropriate composition of the cupronickel alloy, through control of sea water sulphur level, etc.
机译:石化炼油厂粗蒸馏装置的白铜冷凝管的失效分析。发现载有海水的冷凝器管过早损坏,随后全面变薄,形成浅通道,凹坑等,并在其中一个单元中出现灰黑色内部沉积物。在另一个单元中,发现管子发生了故障,而没有任何明显的整体变薄,并且存在粘附的,硬的和黑褐色的沉积物。研究表明,在一种情况下,海水流速的增加以及铁中铁的缺乏导致了失效,而在另一种情况下,与淤泥沉积和生物污垢有关的相对较低的流速是导致失效的原因。案件。可以通过将水速保持在指定范围内,用清水冲洗管,使用和结垢涂料,选择更合适的白铜合金成分,控制海水中的硫含量等来控制管的失效。