A round PHI 78 mm structural steel bar of 42CrMo4 grade with an internal crack was brought with the request to pursue a failure analysis investigation. The crack was detected after ultrasonic inspection at the end-user plant. Visual inspection, optical and scanning electron microscopy were used as the principal analytical techniques in the present study. Further to fractographic interpretation (dendritic morphology found in failure area) and the inclusions detected in the interior of the crack surfaces, it can be concluded that the major crack in the steel bar was probably originated from casting. Plastic deformation processes during rolling resulted probably in the rotation of the crack while overload after subsequent heat treatment (quenching and tempering) may have caused secondary cleavage morphology cracks.
机译:提出了带有内部裂纹的42CrMo4级PHI 78 mm圆形结构钢筋,要求进行破坏分析研究。在最终用户工厂进行超声波检查后,发现了裂纹。目视检查,光学和扫描电子显微镜被用作本研究的主要分析技术。进一步的分形解释(在破坏区域发现树枝状形态)和在裂纹表面内部检测到夹杂物,可以得出结论,钢筋中的主要裂纹可能源自铸造。轧制过程中的塑性变形过程可能导致裂纹旋转,而后续热处理(淬火和回火)后的过载可能导致二次分裂形态裂纹。