YnbO4: Bi phosphor screens deposited by theelectrophoretic deposition method have been examined usinglaser Raman spectroscopy. Evidence was found that screens,which manifested poor performance under cathodoluminescencetesting, were contaminated with Fe3+ ions. The presence of Fe3+ions could only have originated in the stainless steel anode. Thiswork demonstrates the danger of using anodes capable of poisoning the phosphor.
机译:YnbO4:使用激光拉曼光谱法研究了通过电泳沉积法沉积的Bi荧光屏。有证据表明,在阴极发光测试下表现不佳的屏幕被Fe3 +离子污染。 Fe3 +离子的存在只能起源于不锈钢阳极。这项工作证明了使用会中毒磷光体的阳极的危险。