Video manometry of the sphincter of Oddi: a new aid for interpreting manometric tracings and excluding manometric artefacts.

机译:Oddi括约肌的视频测压法:解释测压痕迹和排除测压伪像的新工具。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND AND STUDY AIMS: Endoscopic sphincter of Oddi manometry (ESOM) allows direct assessment of motor function in the sphincter of Oddi. However, variations in examination conditions and duodenal motility may have a critical effect on the results of ESOM. The aim of the present study was to develop a new method sphincter of Oddi video manometry-based on simultaneous ESOM and real-time endoscopic image analysis, and to investigate the usefulness of video manometry for detecting manometric artefacts during ESOM. PATIENTS AND METHODS: Seven consecutive patients who had undergone cholecystectomy and were referred with a suspicion of sphincter of Oddi dysfunction were investigated. Sphincter of Oddi pressure and endoscopic images (20 frames/s) were recorded simultaneously on a Synectics PC Polygraf computer system with a time-correlated basis, and then compared. RESULTS: On ESOM, 69 sphincter of Oddi phasic contractions were identified, with an average amplitude of 153.9+/-85.0 mm Hg and a duration of 7.9+/-1.2 seconds. Visual analysis of the real-time endoscopic images, replayed in cine loop by the computer, revealed 236 separate duodenal contractions, with an average frequency of 3.5+/-2.4/min (range: 1-12/min). On the ESOM tracing, 78% of the duodenal contractions had a corresponding pressure wave with an average duration of 2.8+/-0.4 seconds and an amplitude of 71.9+/-16.7 mm Hg. Other artefacts on the ESOM tracings, such as catheter movements, pseudocontractions, hyperventilation, or retching, were also easily recognized using simultaneous ESOM and real-time endoscopic image analysis. CONCLUSIONS: Video manometry of the sphincter of Oddi is a promising new method for improving the analysis and documentation of ESOM tracings. It has several advantages over the conventional technique, allowing visual detection of duodenal activity and enabling enhanced recognition of other manometric artefacts.
机译:背景和研究目的:内窥镜下的Oddi测压括约肌(ESOM)可以直接评估Oddi的括约肌的运动功能。但是,检查条件和十二指肠蠕动的变化可能会对ESOM的结果产生关键影响。本研究的目的是开发一种基于同步ESOM和实时内窥镜图像分析的Oddi视频测压括约肌新方法,并研究视频测压在ESOM期间检测测压伪像的实用性。病人和方法:调查了连续七例接受了胆囊切除术并被怀疑患有Oddi括约肌功能障碍的患者。在Synectics PC Polygraf计算机系统上以时间相关的方式同时记录Oddi括约肌的压力和内窥镜图像(20帧/秒),然后进行比较。结果:在ESOM上,确认到69个Oddi括约肌括约肌收缩,平均振幅为153.9 +/- 85.0 mm Hg,持续时间为7.9 +/- 1.2秒。实时内窥镜图像的视觉分析(通过计算机在电影循环中回放)显示236个十二指肠收缩,平均频率为3.5 +/- 2.4 / min(范围:1-12 / min)。在ESOM示踪中,78%的十二指肠收缩具有相应的压力波,平均持续时间为2.8 +/- 0.4秒,振幅为71.9 +/- 16.7 mm Hg。通过同时进行ESOM和实时内窥镜图像分析,还可以轻松识别ESOM描迹上的其他伪像,例如导管移动,假性收缩,过度换气或缩回。结论:Oddi括约肌的视频测压是一种有前途的新方法,可以改善ESOM示踪的分析和记录。与常规技术相比,它具有多个优势,可以直观地检测十二指肠活动并可以增强对其他测压伪像的识别。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号