The influence of the reference electrode in recording F-waves.

机译:参比电极在记录F波中的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: To demonstrate that many tibial F-waves can be recorded with the tendon electrode and to declare the importance of the "reference" electrode in F-wave recording. METHODS: In eight lower extremities of four healthy subjects, tibial and fibular F-waves were recorded with the belly and tendon electrodes separately, using the opposite foot electrode as a reference site. RESULTS: It was found that the mean tibial F-wave persistence proportions were 51.5% with the belly electrode and 86.7% with the tendon electrode. A greater number of tibial F-waves were recorded with the tendon electrode than the belly electrode, while few peroneal F-waves were recorded with the tendon electrode. CONCLUSION: Many of the standard tibial F-waves were recorded with the tendon "reference" electrode. SIGNIFICANCE: This phenomenon might be a clue to the difference of the F-wave persistence between the tibial and the peroneal nerves.
机译:目的:证明可以用肌腱电极记录许多胫骨F波,并说明“参考”电极在F波记录中的重要性。方法:在四个健康受试者的八个下肢中,分别使用腹部和腱电极记录胫骨和腓骨F波,并使用相反的脚电极作为参考部位。结果发现,腹部电极的平均胫骨F波持续率为51.5%,腱电极的平均为86.7%。用肌腱电极记录的胫骨F波数量比腹部电极多,而用肌腱电极记录的腓骨F波却很少。结论:许多标准的胫骨F波是用肌腱“参考”电极记录的。重要性:这种现象可能是胫骨和腓神经之间F波持续性不同的线索。