首页> 外文期刊>Irish journal of medical science >The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty
【24h】

The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty

机译:全髋关节置换术中醋酸盐模板的准确性和观察者之间的可靠性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Aim: The accuracy and inter-observer reliability (IOR) of acetate templating on hard copy X-rays in 33 primary total hip arthroplasties as measured by consultant and trainee surgeons was analyzed to find out how accurate are junior surgeons undertaking specialty training. Methods: The study was questionnaire-based using a prospective cohort over a 4 weeks period. The Surgeon measurements of acetabular cup, femoral stem and femoral offset sizes were noted following acetate measurements and then compared with the final implant chosen during surgery. Results: Prediction of sizing to within one size of the final match size was 75 % accurate for cup and 91 % accurate for femoral stem. Prediction of exact femoral offset sizes was 91 % accurate. Templating showed strong IOR between senior consultant surgeon and junior trainee registrar within one size for cup (83 %) and stem (100 %) and for exact hip offset prediction (92 %). Conclusion: We conclude that acetate templating on hard copy X-rays is beneficial to surgeons to gauge acetabular cup and femoral stem size to within one size range. This further helps in predicting nearly exact femoral offset size.
机译:目的:分析由顾问医生和实习医生测量的33例原发性全髋关节置换术中,硬拷贝X射线下的醋酸盐模板在硬拷贝X射线上的准确性和观察者之间的可靠性(IOR),以了解初级医师接受专科培训的准确性。方法:本研究采用前瞻性队列研究,为期4周。在进行乙酸盐测量后,记录外科医生对髋臼杯,股骨干和股骨偏置尺寸的测量结果,然后与手术期间选择的最终植入物进行比较。结果:对于杯的准确度预测为最终尺寸的一倍以内,杯的准确度为75%,股骨柄的准确度为91%。准确的股骨偏移尺寸预测为91%准确。模板显示高级顾问外科医生和初级实习生注册人员之间的IOR值在一个大小范围内,用于杯(83%)和杆(100%)以及精确的髋关节偏移预测(92%)。结论:我们得出的结论是,在硬拷贝X射线上进行醋酸盐模板化有助于外科医生将髋臼杯和股骨柄的尺寸规整在一个尺寸范围内。这进一步有助于预测几乎准确的股骨偏移量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号