...
首页> 外文期刊>International wound journal. >Prevention of pressure ulcer: interaction of body characteristics and different mattresses.
【24h】

Prevention of pressure ulcer: interaction of body characteristics and different mattresses.

机译:预防压疮:身体特征与不同床垫的相互作用。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We analysed the effect of different body features on contact area, interface pressure and pressure distribution of three different mattresses. Thirty-eight volunteers (age ranged from 17 to 73 years, 23 females) were asked to lie on three different mattresses in a random order: I, standard hospital foam mattresses; II, higher specification foam mattresses (Viscorelax Sure(R) ); III, constant low pressure devices (CareMedx(R) , AirSystems). Measurements were performed in supine position and in a 90 degrees left- and right-sided position, respectively, using a full-body mat (pressure mapping device Xsensor X2-Modell). Outcome variables were contact area (CA) in cm(2) , mean interface pressure (IP) in mmHg and pressure distribution (PD) estimated as rate of low pressures between 5 and 33 mmHg on each mattress in percent. Mean CA was lowest in the standard hospital foam mattresses and increased in the higher specification foam mattresses and was highest in the constant low pressure device (supine position: 491 +/- 86 cm(2) , 615 +/- 95 cm(2) , 685 +/- 116 cm(2) ). Mean IP was highest in the standard hospital foam mattresses and lower but similar in the higher specification foam mattresses and the constant low pressure devices (supine position: 22.3 +/- 1.5 mmHg, 17.6 +/- 1.7 mmHg, 17.6 +/- 2.2 mmHg). Models were estimated for CA, IP and PD including the independent variables height, weight and waist-to-hip-ratio (WHR). They show that body morphology seems to play a minor role for CA, IP and PD, but very thin and tall patients and very small and obese people might benefit from different mattresses. Our data show that CA increases with increasing specification of mattresses. Higher specification foam mattresses and constant low pressure devices show similar IP, but constant low pressure devices show a wider pressure distribution. Body morphology should be considered to optimise prevention for single patients.
机译:我们分析了不同身体特征对三种不同床垫的接触面积,界面压力和压力分布的影响。 38名志愿者(年龄在17至73岁之间,23名女性)被要求随机躺在三个不同的床垫上:I,标准的医院泡沫床垫; II,更高规格的泡沫床垫(Viscorelax Sure(R)); III,恒定低压装置(CareMedx,AirSystems)。使用全身垫(压力测绘仪Xsensor X2-Model1)分别在仰卧位置和左右90度位置进行测量。结果变量是接触面积(CA)单位为cm(2),平均界面压力(IP)单位为mmHg和压力分布(PD),以每个床垫上5到33 mmHg之间的低压比率(以百分比表示)估算。平均CA在标准医院泡沫床垫中最低,而在更高规格的泡沫床垫中则增加,在恒定低压装置中最高(仰卧位:491 +/- 86 cm(2),615 +/- 95 cm(2) ,685 +/- 116厘米(2))。标准医院用泡沫床垫的平均IP最高,而较高规格的泡沫床垫和恒定低压设备的平均IP较低(仰卧位:22.3 +/- 1.5 mmHg,17.6 +/- 1.7 mmHg,17.6 +/- 2.2 mmHg )。对CA,IP和PD的模型进行了估计,包括独立变量的身高,体重和腰臀比(WHR)。他们表明,身体形态似乎对CA,IP和PD的作用很小,但是非常瘦高的患者以及非常小的肥胖的人可能会受益于不同的床垫。我们的数据表明,CA随着床垫规格的增加而增加。更高规格的泡沫床垫和恒定低压设备显示出相似的IP,但恒定低压设备显示出更宽的压力分布。应考虑身体形态以优化单身患者的预防。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号