首页> 外文期刊>Investigative ophthalmology & visual science >Asymmetry in optic disc morphometry as measured by heidelberg retina tomography in a normal elderly population: the Bridlington Eye Assessment Project.
【24h】

Asymmetry in optic disc morphometry as measured by heidelberg retina tomography in a normal elderly population: the Bridlington Eye Assessment Project.

机译:正常老年人群中通过海德堡视网膜断层扫描测量的视盘形态测量中的不对称性:Bridlington眼评估项目。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To define the normal range of asymmetry in optic disc parameters measured by the Heidelberg Retina Tomograph (HRT II; Heidelberg Engineering GmbH, Dossenheim, Germany) in a normal elderly population. METHODS: Optic disc analysis of 918 eyes of 459 normal elderly patients was performed. All patients were consecutive in a cohort screened for eye disease. Normality was defined with a normal visual field on automated suprathreshold screening, intraocular pressure less than 22 mm Hg, and minimum corrected visual acuity of 6/12. Asymmetry measures were calculated by subtracting the values of the smaller disc from those of the larger disc. RESULTS: Subjects' mean age (262 female and 197 male) was 72.6 years (range, 65.5-89.3). There was no significant difference in disc area or rim area between the right and left eyes. Neither rim-to-disc area ratio asymmetry nor rim measurement asymmetries were significantly affected by age or sex. Rim-to-disc area ratio asymmetry was much less affected by the increasing difference in disc size than was absolute rim asymmetry. The 2.5th and 97.5th percentile limits of normality for the rim-to-disc area ratio asymmetry in the global and temporal-inferior analyses were -0.212 and 0.154, and -0.331 and 0.261, respectively. CONCLUSIONS: The normal range of parameter asymmetry in an age group relevant to glaucoma may be useful in the discrimination of normal from early glaucoma. Asymmetry analysis may improve discriminatory ability by reducing parameter variability based on disc size. The rim-to-disc area ratio asymmetry measure is likely to be the most useful parameter in describing normality with consistency.
机译:目的:确定正常老年人群中由海德堡视网膜断层扫描仪(HRT II;海德堡工程有限公司,德国多森海姆)测量的视盘参数的正常不对称范围。方法:对459例正常老年患者的918只眼进行了视盘分析。所有患者均连续接受筛查眼疾。通过自动阈上筛查的正常视野,眼内压低于22 mm Hg以及最低矫正视力为6/12来定义正常度。通过从较大圆盘的值中减去较小圆盘的值来计算不对称度量。结果:受试者的平均年龄(262名女性和197名男性)为72.6岁(范围65.5-89.3)。左右眼之间的椎间盘区域或边缘区域没有显着差异。轮辋面积比的不对称性和轮辋尺寸的不对称性均不受年龄或性别的影响。碟片与碟片的面积比不对称性受碟片大小差异的增加的影响远小于绝对轮辋不对称性。在全局和时间劣势分析中,边缘与磁盘面积比不对称的正态性的第2.5个和第97.5个百分位数限制分别为-0.212和0.154,以及-0.331和0.261。结论:与青光眼有关的年龄组中参数不对称的正常范围可能有助于区分正常人与早期青光眼。不对称分析可以通过减少基于光盘大小的参数可变性来提高区分能力。圆盘面积比不对称性度量可能是描述具有一致性的正态性时最有用的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号