首页> 外文期刊>Investigative ophthalmology & visual science >Qualitative assessment of ultrasound biomicroscopic images using standard photographs: the liwan eye study.
【24h】

Qualitative assessment of ultrasound biomicroscopic images using standard photographs: the liwan eye study.

机译:使用标准照片对超声生物显微图像进行定性评估:荔湾眼研究。

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes.
机译:目的。通过基于超声生物显微镜(UBM)图像的定性评估系统对与前房角有关的解剖特征进行分类。方法。原发性闭角型可疑病例(PACS),由有色小梁网定义,在静态角膜镜检查的两个或多个象限中不可见(病例),并且系统地选择了不符合此标准的受试者(每10个中的1个)(对照)在中国广州进行的基于人口的调查中被纳入。所有科目都经过了UBM考试。使用一组标准UBM图像定性地分类与角度配置相关的解剖特征,包括虹膜厚度,虹膜凸度,虹膜成角度,睫状体大小和睫状突位置。所有分析都是在右眼图像上进行的。结果。根据定性等级,在角度镜狭窄的眼睛(n = 117)和对照眼睛(n = 57)之间,总虹膜厚度的差异无统计学意义。在PACS眼的所有象限中,虹膜周围三分之一的虹膜往往较厚,尽管差异仅在上象限具有统计学意义(P = 0.008)。在虹膜插入,虹膜角度,睫状体大小和睫状突位置的定性分类中没有发现显着差异。当与所有象限中具有广角的对照组眼睛进行比较时,发现相似。结论基底虹膜厚度似乎与窄角构型比与整体虹膜厚度更相关。否则,在窄角和广角眼中,睫状体的前旋转和大小,虹膜插入以及整个虹膜厚度是可比的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号