首页> 外文期刊>International Journal of Thermal Sciences >Thermal-flow characteristics of the new wave-finned flat tube bundles in air-cooled condensers
【24h】

Thermal-flow characteristics of the new wave-finned flat tube bundles in air-cooled condensers

机译:风冷式冷凝器中新型波状扁平管束的热流特性

获取原文
获取原文并翻译 | 示例
           

摘要

The wave-finned flat tube heat exchangers are widely used in air-cooled condensers of a power plant. Due to the oblique arrangement of the wavy fins on the A-frame tube bundles of the air-cooled condenser, the finned tube is prone to fouling thus the thermo-flow performances of air-cooled condensers are likely to become deteriorated. A new configuration of wave-finned flat tube, in which the fin surface rotates to be perpendicular, is proposed in this paper to prevent the fouling from gathering on the finned tube. The physical and mathematical models for the fluid and heat flows of the cooling air through the present and proposed wave-finned flat tube bundles are setup, and the thermo-flow characteristics are compared. For the proposed finned tube, the influences of the fin pitch, height and the Reynolds number on the flow and heat transfer performances are investigated, and the correlations of the friction factor and Nusselt number are recommended. The results show that the buoyancy effect should be taken into account for the correlation of the friction factor at low Reynolds numbers, but this buoyancy force can be ignored for the Nusselt number.
机译:波纹翅片扁平管换热器广泛用于电厂的风冷冷凝器。由于波状翅片在风冷冷凝器的A形管束上的倾斜布置,翅片管容易结垢,因此风冷冷凝器的热流性能可能变差。为了防止结垢积聚在翅片管上,本文提出了一种新的结构,即翅片表面旋转成垂直方向的翅片管。建立了通过当前和拟议的波浪翅片扁平管束的冷却空气的流体和热流的物理和数学模型,并比较了热流特性。对于拟议的翅片管,研究了翅片间距,高度和雷诺数对流动和传热性能的影响,并建议了摩擦系数和努塞尔数的相关性。结果表明,在低雷诺数下,应考虑浮力效应与摩擦系数的相关性,但对于努塞尔特数,该浮力可以忽略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号