Objective: At our center, the Maico MB11 BERAphone ? device is used for newborn hearing screening based on Auditory Brainstem Responses (ABR). In 2006, an optimized chirp stimulus was implemented in the device to increase the reliability and quality of the screening method. In 2002, an automated response detection algorithm had been implemented. This study analyzes the screening results using the MB11 BERAphone ? device with the implemented chirp stimulus and automated response detection method. Methods: The data presented were collected in the well-baby nursery as part of the newborn hearing screening program following a two stage screening protocol. To focus the study on the typical routine screening, data from at-risk babies were not included. Overall, data from 6866 babies (3604 males and 3262 females) screened from March 2006 to April 2011 were analyzed in this study. Results: Out of the 6866 babies screened, 6607 passed bilaterally prior to hospital discharge (defined as 1st stage in this hearing screening program). Therefore, the pre-discharge pass rate of the hearing screening with the MB11 BERAphone ? device was 96.2%. The resulting referral rate was 3.8%. The median test time per ear (excluding time for preparation and data reporting) was 28s with a range of 15-112s (5-95th percentile).The number of infants referred for 2nd stage, post-discharge re-screening was 259. Of this group, 71 passed bilaterally and 188 failed the re-screening in one or both ears. Therefore, including both the pre-discharge and post-discharge screening results, the bilateral pass rate was 97.3% and 2.7% were referred for diagnostic evaluation.Diagnostic testing was performed on all of the 188 infants who were referred. Results showed that 47 of these babies had hearing loss. This equates to a positive predictive value for a refer result of 25%. The observed prevalence of hearing impairment in our population was 0.684%.Diagnostic results for 141 of the referred newborns proved that they had normal hearing. That is, 141 out of 6866 newborns had a false-positive result with the MB11 BERAphone ? screening. Therefore, the device had a specificity of 97.9%. During the time period of this study, no baby who passed the hearing screening was later found to have hearing impairment, suggesting a sensitivity of 100%. However, due to the limited number of newborns and the short time period after screening for the more recently screened babies, a reliable estimate of the sensitivity cannot be yet made from our program statistics. The theoretical sensitivity of the MB 11 device is 99.9%. Conclusions: The Maico MB11 BERAphone ? is a reliable device for auditory brainstem response newborn hearing screening and it provides results within a very short time. Due to the implemented method for automatic detection of ABR, the use of the device does not require an experienced examiner, allowing it to be used by trained technicians in locations outside the department of audiology such as the well-baby nursery.
机译:目标:在我们中心,Maico MB11 BERAphone是什么?该设备用于基于听觉脑干反应(ABR)的新生儿听力筛查。 2006年,在设备中实施了优化的线性调频刺激,以提高筛选方法的可靠性和质量。 2002年,实施了自动响应检测算法。本研究使用MB11 BERAphone™分析筛选结果。具有chi声刺激和自动响应检测方法的设备。方法:按照两个阶段的筛查方案,在新生儿听力筛查计划的一部分中,在好孩子的托儿所收集数据。为了将研究重点放在典型的常规筛查上,不包括来自高危婴儿的数据。总体而言,本研究分析了2006年3月至2011年4月筛查的6866例婴儿(3604例男性和3262例女性)的数据。结果:在筛查的6866例婴儿中,有6607例在出院前通过了双侧检查(在此听力筛查程序中定义为第一阶段)。因此,使用MB11 BERAphone™进行听力筛查的放电前通过率是多少?装置为96.2%。产生的推荐率为3.8%。每只耳朵的平均测试时间(不包括准备时间和数据报告时间)为28s,范围为15-112s(5-95%)。第二阶段出院后重新筛查的婴儿人数为259。该组中有71例通过了双边检查,而188例没有通过一只或两只耳朵进行重新筛查。因此,包括出院前和出院后的筛查结果,双侧通过率分别为97.3%和2.7%用于诊断评估。对所有188例被转诊的婴儿进行了诊断测试。结果显示,这些婴儿中有47名患有听力障碍。对于25%的参考结果,这等于阳性预测值。在我们的人群中,观察到的听力障碍患病率为0.684%.141名被推荐新生儿的诊断结果证明他们的听力正常。也就是说,在6866名新生儿中,有141名MB11 BERAphone的结果为假阳性。筛选。因此,该装置的特异性为97.9%。在本研究期间,以后没有发现通过听力筛查的婴儿有听力障碍,表明敏感性为100%。但是,由于新生儿数量有限,并且在筛查较新筛查的婴儿后时间较短,因此无法从我们的计划统计数据中可靠地估算出敏感性。 MB 11器件的理论灵敏度为99.9%。结论:Maico MB11 BERAphone?是用于听觉脑干反应新生儿听力筛查的可靠设备,可在非常短的时间内提供结果。由于采用了用于自动检测ABR的方法,因此该设备的使用不需要有经验的检查员,从而允许受过训练的技术人员在听力学部门之外的位置(例如,婴儿保育所)使用该设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号