首页> 外文期刊>British Journal of Radiology >Characterisation of dose distribution in linear accelerator-based intracranial stereotactic radiosurgery with the dynamic conformal arc technique: consideration of the optimal method for dose prescription and evaluation.
【24h】

Characterisation of dose distribution in linear accelerator-based intracranial stereotactic radiosurgery with the dynamic conformal arc technique: consideration of the optimal method for dose prescription and evaluation.

机译:基于动态加速弧技术的基于线性加速器的颅内立体定向放射外科手术中剂量分布的表征:考虑剂量处方和评估的最佳方法。

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study was to characterise dose distribution in linear accelerator-based intracranial stereotactic radiosurgery using the dynamic conformal arc technique, and to validate the pertinence of dose prescription to the specific percentage isodose surface (IDS).73 plans for brain metastases were reviewed and replanned with a uniform method for target definition and treatment planning.In all cases except 1 the dose prescription to the 80% IDS satisfied the criteria of the standardised prescription IDS as previously proposed. However, both of the planning target volume (PTV) coverage values for the 80% and 90% IDSs and the PTV D99 and D95 (IDS receiving at least 99% or 95% of the PTV) were inconsistent and significantly increased as a function of the PTV size. The 80% IDS for a PTV of more than 5 cm(3) achieved adequate PTV coverage without a leaf margin. The dose conformity for 80% IDS gradually worsened as the PTV increased, whereas that for the PTV D99 or D95 improved as a function of the PTV size. The addition of a leaf margin attained 100% PTV coverage for 80% IDS, while leading to a poorer dose conformity.The dose prescription to the specific percentage IDS does not necessarily guarantee consistent target coverage, D99 and D95, and desirable dose conformity in proportion to the target volume. The dose prescription and evaluation at the specific target coverage would therefore be preferable as an objective method in order to report the "marginal dose" and to clearly compare the planning parameters with those from other modalities.
机译:这项研究的目的是使用动态保形弧技术表征基于线性加速器的颅内立体定向放射外科手术中的剂量分布,并验证剂量处方与特定等剂量表面(IDS)的相关性。审查了73种脑转移计划在除1以外的所有情况下,达到80%IDS的剂量处方均符合先前提议的标准化处方IDS的标准。但是,对于80%和90%的IDS以及PTV D99和D95(IDS至少接收PTV的99%或95%)的规划目标量(PTV)覆盖率值均不一致,并且随着PTV大小。大于5 cm(3)的PTV的80%IDS实现了足够的PTV覆盖,没有叶子边缘。随着PTV的增加,80%IDS的剂量一致性逐渐恶化,而PTV D99或D95的剂量一致性随PTV大小的变化而提高。叶缘的增加使80%IDS的PTV覆盖率达到100%,同时导致较差的剂量符合性.IDS特定百分比的剂量处方并不一定保证目标覆盖率,D99和D95保持一致,以及所需的剂量符合性比例达到目标音量。因此,为了报告“边际剂量”并清楚地将计划参数与其他方式的计划参数进行比较,在特定目标覆盖率下进行剂量处方和评估将是优选的客观方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号