首页> 外文期刊>International journal of laboratory hematology >Neutrophil volume, conductivity and scatter parameters with effective modeling of molecular activity statistical program gives better results in neonatal sepsis
【24h】

Neutrophil volume, conductivity and scatter parameters with effective modeling of molecular activity statistical program gives better results in neonatal sepsis

机译:中性粒细胞的体积,电导率和散射参数以及分子活性统计程序的有效建模可为新生儿败血症提供更好的结果

获取原文
获取原文并翻译 | 示例

摘要

Introduction: Neonatal sepsis remains an important clinical syndrome despite advances in neonatology. Current hematology analyzers can determine cell volume (V), conductivity for internal composition of cell (C) and light scatter for cytoplasmic granularity and nuclear structure (S), and standard deviations which are effective in the diagnosis of sepsis. Statistical models can be used to strengthen the diagnosis. Effective modeling of molecular activity (EMMA) uses combinatorial algorithm of the selection parameters for regression equation based on modified stepwise procedure. It allows obtaining different regression models with different combinations of parameters. Methods: We investigated these parameters in screening of neonatal sepsis. We used LH780 hematological analyzer (Beckman Coulter, Fullerton, CA, USA). We combined these parameters with interleukin-6 (IL-6) and C-reactive protein (CRP) and developed models by EMMA. Results: A total of 304 newborns, 76 proven sepsis, 130 clinical sepsis and 98 controls, were enrolled in the study. Mean neutrophil volume (MNV) and volume distribution width (VDW) were higher in both proven and clinical sepsis groups. We developed three models using MNV, VDW, IL-6, and CRP. These models gave more sensitivity and specificity than the usage of each marker alone. Conclusions: We suggest to use the combination of MNV and VDW with markers such as CRP and IL-6, and use diagnostic models created by EMMA.
机译:简介:尽管新生儿病学有所进步,但新生儿败血症仍是重要的临床综合征。当前的血液分析仪可以确定细胞体积(V),细胞内部组成的电导率(C)和细胞质粒度和核结构的光散射(S)以及对败血症的诊断有效的标准偏差。统计模型可以用来加强诊断。有效的分子活性建模(EMMA)使用基于改进的逐步过程的回归方程选择参数组合算法。它允许获得具有不同参数组合的不同回归模型。方法:我们调查了这些参数,以筛查新生儿败血症。我们使用了LH780血液分析仪(贝克曼库尔特公司,美国加利福尼亚州富勒顿)。我们将这些参数与白介素6(IL-6)和C反应蛋白(CRP)相结合,并通过EMMA开发了模型。结果:共纳入304例新生儿,76例经证实的败血症,130例临床败血症和98例对照。在已证实的败血症组和临床败血症组中,平均中性粒细胞体积(MNV)和体积分布宽度(VDW)较高。我们使用MNV,VDW,IL-6和CRP开发了三种模型。这些模型比单独使用每种标记物具有更高的灵敏度和特异性。结论:我们建议将MNV和VDW与CRP和IL-6等标记结合使用,并使用EMMA建立的诊断模型。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号