首页> 外文期刊>International Journal of Cardiology >Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis
【24h】

Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis

机译:压平眼压法测量非侵入性获得的中心血压的准确性:系统评价和荟萃分析

获取原文
获取原文并翻译 | 示例
           

摘要

Background and objectives: Non-invasive methods based on applanation tonometry have been proposed to estimate central blood pressure. However, the accuracy of these methods hasn't been systematically examined. Methods: We performed a systematic review and meta-analysis of studies comparing estimated and invasively measured central BP. Results: Sufficient data were available in 22 studies for meta-analysis (857 subjects and 1167 measurements). Acquired arterial pressure waveforms in these studies were directly measured, calibrated to match invasive aortic mean BP and diastolic BP or calibrated to match brachial BP measured with a sphygmomanometer, cuff BP. Of the former 2 conditions, the errors of estimated central BP were small with a mean and standard deviation of difference - 1.1 ± 4.1 mm Hg (95% limits of agreement - 9.1-6.9 mm Hg) for central systolic BP; - 0.5 ± 2.1 mm Hg (- 4.6-3.6 mm Hg) for central diastolic BP; and - 0.8 ± 5.1 mm Hg (- 10.8-9.2 mm Hg) for central pulse pressure. However, the errors inflated to - 8.2 ± 10.3 mm Hg (- 28.4-12.0 mm Hg) for central systolic BP, 7.6 ± 8.7 mm Hg (- 9.5-24.6 mm Hg) for central diastolic BP, and - 12.2 ± 10.4 mm Hg (- 32.5-8.1 mm Hg) for central pulse pressure, when calibrated to cuff BP. The findings were still evident in subgroup analysis conducted with different central BP estimating methods and validated cuff BP monitors. Conclusion: Present tonometry-based central BP estimating methods are acceptable in theory, with small errors. However, based on current available evidence, there is substantial room for improvement in measurement accuracy of central BP when cuff BP is used to calibrate the peripheral waveforms.
机译:背景与目的:已经提出了基于压平眼压法的非侵入性方法来估计中心血压。但是,这些方法的准确性尚未得到系统地检查。方法:我们对比较估计的和有创测量的中央血压进行了系统的回顾和荟萃分析。结果:在22项荟萃分析研究中有足够的数据(857名受试者和1167项测量值)。对这些研究中获得的动脉压波形进行直接测量,校准以匹配有创主动脉平均BP和舒张压BP或校准以匹配使用血压计,袖带BP测量的肱动脉BP。在前两种情况中,估计的中心血压的误差很小,中心收缩压的平均和标准差为-1.1±4.1 mm Hg(95%一致极限-9.1-6.9 mm Hg); -0.5±2.1 mm Hg(-4.6-3.6 mm Hg)用于中心舒张压BP;和-0.8±5.1 mm Hg(-10.8-9.2 mm Hg)用于中心脉冲压力。但是,对于中央收缩压,误差膨胀为-8.2±10.3 mm Hg(-28.4-12.0 mm Hg),对于心脏舒张压膨胀为7.6±8.7 mm Hg(-9.5-24.6 mm Hg),以及-12.2±10.4 mm Hg当校准至袖带BP时,中心脉压为(-32.5-8.1 mm Hg)。在使用不同的中央BP估计方法和经过验证的袖带BP监测仪进行的亚组分析中,这些发现仍然很明显。结论:目前基于眼压测量的中央BP估计方法在理论上是可以接受的,误差很小。但是,根据现有证据,当使用袖带BP校准周围波形时,中央BP的测量精度仍有很大的提高空间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号