How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram

机译:脉搏率变异性作为心率变异性评估的准确性有多高?:一项关于光体积描记技术与心电图比较研究的综述

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV. Methods: We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography). Results/conclusions: Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
机译:背景:心率变异性(HRV)作为临床研究和诊断工具的有用性已在众多研究中得到证实。黄金标准技术包括根据心电图信号分析RR间隔的时间序列。但是,一些作者使用了脉冲周期间隔而不是RR间隔,因为可以从脉搏波(例如光电容积描记)信号中确定脉冲间隔。此选项通常称为脉搏率变异性(PRV),利用它可以扩展脉搏血氧仪的适用性或简化HRV的动态监测。方法:我们回顾了研究PRV作为HRV估计值的准确性的研究,而与基础技术(光体积描记法,连续血压监测或Finapresi,阻抗体积描记法)无关。结果/结论:尽管许多研究表明,PRV会高估短期变异性,但结果表明受试者在静止时应具有足够的准确性,这反映了呼吸与心血管系统之间的耦合作用。体力活动和一些精神压力似乎在很大程度上削弱了PRV和HRV的一致性。关于传感器位置或检测算法的发现不是结论性的。通常,由于不同的实验设置和/或分析方法,不同研究的结果几乎是不可估量的事实,阻碍了定量结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号