首页> 外文期刊>International Journal of Biometeorology: Journal of the International Society of Biometeorology >Effect of micro mist sauna bathing on thermoregulatory and circulatory functions and thermal sensation in humans
【24h】

Effect of micro mist sauna bathing on thermoregulatory and circulatory functions and thermal sensation in humans

机译:微雾桑拿浴对人体温度调节和循环功能及热感觉的影响

获取原文
获取原文并翻译 | 示例
           

摘要

To examine the effects of micro mist sauna bathing, produced by water crushing method, we exposed ten male subjects to five cases of micro mist sauna, namely (1) room temperature (RT) 38 A degrees C with 100 % (actually 91 %) relative humidity (RH), (2) RT 41.5 A degrees C with 80 % (actually 81 %) RH, (3) RT 41.5 A degrees C with 100 % (actually 96 %) RH, (4) RT 45.0 A degrees C with 64 % (actually 61 %) RH, and (5) RT 45.0 A degrees C with 100 % (actually 86 %) RH, and measured tympanic temperature, mean skin temperature, heart rate (HR), and cheek moisture content, as well as ratings of thermal and sweating sensation tympanic temperatures at RT 45 A degrees C were significantly higher at 86 % RH than those at 61 % RH; however, those at RT 45 A degrees C with 61 % RH were higher than those with 86 % RH during recovery. There were no significant differences at RT 41.5 A degrees C between with 81 % RH and with 96 % RH. Mean skin temperature was the highest at RT 45 A degrees C 86 % RH case, followed by at RT 41.5 A degrees C 96 % RH, RT 45 A degrees C 61 % RH, RT 41.5 A degrees C 81 % RH, and finally at RT 38 A degrees C 91 % RH. HR change showed the same order as for mean skin temperature. A significant difference in cheek moisture content was observed between RT 41.5 A degrees C with 81 % RH and RT 45 A degrees C with 86 % RH 10 min after the micro mist bathing. There were no significant differences between ratings of thermal sensation at RT 41.5 A degrees C with 81 % RH and at RT 45 A degrees C with 61 % RH and RT 45 A degrees C with 61 % RH and RT 45 A degrees C with 86 % RH. Between RT 45 A degrees C with 86 % RH and RT 41.5 A degrees C with 81 % RH, there was a tendency for interaction (0.05 p 0.1). Other cases showed significant higher ratings of thermal sensation at higher room temperature or higher relative humidity. The ratings of sweating sensation 10 min after the mist sauna bathing were significantly higher at higher RT and RH except between RT 41.5 A degrees C 96 % RH and RT 45 A degrees C 86 % RH which exhibited no significant difference. We concluded that the micro mist sauna produced by water crushing method induced more moderate and effective thermal effect during micro mist sauna bathing than the conventional mist sauna bathing. In addition, micro mist sauna is as effective for heating the human subjects as bathtub bathing as well as more moderate thermal and sweating sensations.
机译:为了检查通过压水法产生的微雾桑拿浴的效果,我们将十名男性受试者暴露于五例微雾桑拿浴中,即(1)室温(RT)38 A时100%(实际为91%)相对湿度(RH),(2)相对湿度80%(实际为81%)的RT 41.5 A摄氏度,(3)相对湿度100%(实际为96%)的RT 41.5 A摄氏度,(4)相对湿度45.0 A摄氏度相对湿度为64%(实际为61%),并且(5)相对湿度为45.0 A,相对湿度为100%(实际为86%),并测量鼓膜温度,平均皮肤温度,心率(HR)和脸颊水分含量,在RT 45 A摄氏度下,相对于61%RH,热和汗感鼓膜温度等级在86%RH时明显更高;然而,在恢复过程中,在相对湿度为61%的RT 45 A摄氏度下,其相对高于那些在相对湿度为86%的条件下。在相对湿度为81%和相对湿度为96%的条件下,在RT 41.5 A摄氏度下无显着差异。在RT 45 A摄氏度86%RH的情况下,平均皮肤温度最高,其次在RT 41.5 A摄氏度96%RH,RT 45 A摄氏度61%RH,RT 41.5 A摄氏度81%RH,最后是室温38 A摄氏度91%RH。心率变化显示与平均皮肤温度相同的顺序。在微雾沐浴后10分钟,在相对湿度为81%的RT 41.5 A摄氏度和相对湿度为86%的RT 45 A摄氏度之间,脸颊含水量存在显着差异。在相对湿度为81%的RT 41.5 A摄氏度和相对湿度为61%的RT 45 A摄氏度,相对湿度为61%RH的RT 45 A摄氏度和相对湿度为86%的RT 45 A摄氏度之间的热感等级之间没有显着差异RH。在相对湿度为86%的RT 45 A摄氏度和相对湿度为81%的RT 41.5 A摄氏度之间,存在相互作用的趋势(0.05 <0.1)。其他情况在较高的室温或较高的相对湿度下显示出明显较高的热感等级。在较高的RT和RH下,雾桑拿浴后10分钟的出汗感觉等级显着更高,除了在RT 41.5 A摄氏度96%RH和RT 45 A摄氏度86%RH之间没有显着差异。我们得出的结论是,与常规的薄雾桑拿浴相比,通过水压法生产的微薄雾桑拿浴在微薄雾桑拿浴中诱导了更适度和有效的热效应。此外,微雾桑拿浴与加热浴缸一样有效,可加热人体,并具有适度的热感和出汗感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号