...
首页> 外文期刊>International journal of behavioral medicine >Agreement in regard to total sleep time during a nap obtained via a sleep polygraph and accelerometer: a comparison of different sensitivity thresholds of the accelerometer.
【24h】

Agreement in regard to total sleep time during a nap obtained via a sleep polygraph and accelerometer: a comparison of different sensitivity thresholds of the accelerometer.

机译:通过睡眠测谎仪和加速度计获得的关于小睡期间总睡眠时间的协议:加速度计不同灵敏度阈值的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Appropriate sensitivity threshold of accelerometer to measure total sleep time during nap is not established.Actigraphy-derived total sleep times during naps were calculated using three different sensitivity threshold values and compared with polysomnography.The mean age of the 60 subjects (53 men and 7 women) was 22.8, ranging from 22 to 27?years. Determination of the sleep stage by the polygraph and the sleep/wake judgment by the accelerometer obeyed the sleep/wake judgment, and the accelerometer was monitored under different sensitivity threshold settings. The study was carried out during one afternoon with a 3-h nap opportunity. Kappa statistics, correlations, and several indices of accuracy were compared using statistical methods.The mean total sleep times during a nap set for 180?min were 160.4, 151.8, and 140.5?min, respectively, as judged under the low-sensitive, middle-sensitive, high-sensitive settings of an accelerometer worn on the non-dominant wrist. The corresponding mean total sleep time as calculated using a sleep polygraph was 133.0?min. Sleep/wake judgment by three levels of threshold values for the accelerometer showed that high-sensitive threshold showed relatively high specificity (0.452) compared with specificities by the low-sensitive threshold (0.249) or by the middle-sensitive threshold (0.358). The concordance correlation coefficients and 95% confidence intervals (in parenthesis) between the total sleep time judged by polygraph and low-sensitive, middle-sensitive, or high-sensitive accelerometer were 0.40 (0.26-0.51), 0.53 (0.38-0.65), and 0.64 (0.49-0.75), respectively. The Bland-Altman plot of the measurements showed higher agreement between the total sleep time by polygraph and by the accelerometer using the high-sensitive threshold.From the result obtained in this study, the high-sensitive accelerometer showed the strongest agreement of total sleep time and sleep/wake judgment with the calculated value using the sleep polygraph.
机译:未建立适当的加速度计敏感度阈值来测量午睡的总睡眠时间,使用三种不同的敏感度阈值来计算由活动照相法得出的小睡期间的总睡眠时间,并与多导睡眠监测仪进行比较.60名受试者的平均年龄(53名男性和7名女性) )是22.8岁,从22到27岁不等。通过测谎仪确定睡眠阶段,并通过加速度计进行睡眠/唤醒判断,服从睡眠/唤醒判断,并在不同的灵敏度阈值设置下监控加速度计。该研究在一个下午进行,午睡时间为3小时。使用统计方法比较了Kappa的统计量,相关性和几个准确性指标。根据低敏感度,中等程度的判断,午睡时间180分钟的平均总睡眠时间分别为160.4、151.8和140.5?min非主要手腕上佩戴的加速度计的灵敏性,高灵敏性设置。使用睡眠测谎仪计算出的相应平均总睡眠时间为133.0?min。通过对加速度计的三个阈值级别的睡眠/唤醒判断显示,与低敏感度阈值(0.249)或中敏感度阈值(0.358)的特异性相比,高敏感度阈值显示相对较高的特异性(0.452)。由测谎仪判断的总睡眠时间与低敏感度,中敏感度或高敏感度加速度计之间的一致性相关系数和95%置信区间(用括号括起来)分别为0.40(0.26-0.51),0.53(0.38-0.65),和0.64(0.49-0.75)。测量的Bland-Altman图显示,通过测谎仪和使用高灵敏度阈值的加速度计,总睡眠时间之间的一致性更高。从本研究获得的结果来看,高灵敏度加速度计显示出总睡眠时间的最强一致性并使用睡眠测谎仪根据计算出的值进行睡眠/唤醒判断。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号