首页> 外文期刊>International journal of applied electromagnetics and mechanics >Sizing of defects in special shaped coolant pipe of Tokamak magnet based on eddy current testing signals
【24h】

Sizing of defects in special shaped coolant pipe of Tokamak magnet based on eddy current testing signals

机译:基于涡流测试信号的托卡马克磁体异型冷却剂管道缺陷尺寸

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, quantitative evaluation of defects in an outer-square-inner-round (OSIR), aluminum pipe, which is used as the coolant pipe of Tokamak superconducting magnet, is conducted based on the eddy current testing (ECT) technique. First, numerical simulations to predict ECT signal due to defects in OSIR pipes are performed using a code of A(r) method; Second, ECT signal is detected using an Eddyfi ECT instrument with an absolute pancake ECT probe; Finally, the defect profile in OSIR pipe is reconstructed from the experimental ECT signals with the help of a fast-forward ECT solver, the developed multiple databases strategy and the deterministic inversion algorithm.
机译:在这项研究中,基于涡电流测试(ECT)技术对用作托卡马克超导磁体冷却剂管的外圆内圆(OSIR)铝管中的缺陷进行了定量评估。首先,使用A(r)方法的代码执行数值模拟以预测由于OSIR管道中的缺陷而产生的ECT信号;其次,使用带有绝对煎饼饼ECT探头的Eddyfi ECT仪器检测ECT信号;最后,借助快速前进的ECT求解器,开发的多数据库策略和确定性反演算法,根据实验ECT信号重建OSIR管道中的缺陷轮廓。