This paper discusses the feasibility of determining the thickness of Ni-based alloy sprayed coatings that have been heated in plant environments using swept frequency eddy current testing based on the measurement of the impedance spectrum of the measurement coil. Through a comparison of the experimental and computed signals, an electromagnetic model simulating the test geometry including the coating and the substrate is presented, with particular focus on the effects of heat treatment. Using these models, the coating thickness is estimated using the measured impedance spectra, and the estimation error was found to be around 30 mm.
机译:本文讨论了基于测量线圈阻抗谱的测量,使用扫频涡流测试来确定在工厂环境中已加热的镍基合金喷涂涂层厚度的可行性。通过对实验信号和计算信号的比较,提出了一种电磁模型,该模型模拟了包括涂层和基材在内的测试几何形状,尤其着眼于热处理效果。使用这些模型,使用测得的阻抗谱估算涂层厚度,发现估算误差约为30 mm。