首页> 外文期刊>International archives of occupational and environmental health: Internationales Archiv fur Arbeits- und Umweltmedizin >Assessment of room temperature influence on finger blood flow response induced by short-term grasping of vibrating handle.
【24h】

Assessment of room temperature influence on finger blood flow response induced by short-term grasping of vibrating handle.

机译:评估室温对短期握住振动手柄引起的手指血流反应的影响。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: To investigate the influence of room temperature on finger blood flow (FBF) change in healthy subjects exposed to short-term grasping of a vibrating handle under different room temperatures. METHODS: FBF was measured using a blood flowmeter in six male subjects on the dorsum of the middle phalanx of third finger in both hands once at the end of every minute for an equal duration of 5 min at pre-exposure, during exposure to grasping of vibrating handle with sinusoidal vibration and after exposure. Vibration was generated with a frequency of 125 Hz and an rms acceleration of 40 m/s(2). Measurements were conducted in four room temperatures of 15+/-1, 20+/-1, 25+/-1 and 30+/-1 degrees C. RESULTS: Compared with the baseline measurements in the exposed hand during grasping of vibrating handle most significant increase in FBF was observed at 15+/-1 degrees C (P<0.001) and least at 30+/-1 degrees C (P<0.05), and after vibration least significant FBF was found at 25+/-1 degrees C (P<0.05). In case of the unexposed hand significant increase in FBF was exhibited at 20+/-1 degrees C (P<0.01) and 30+/-1 degrees C (P<0.01) during vibration, and only at 15+/-1 degrees C (P<0.05) after vibration. CONCLUSIONS: Response in FBF due to grasping of vibrating handle was of different patterns from the baseline measurement under different room temperature conditions in both exposed and unexposed hands and it was influenced by room temperature. Overall, the influence was greater at lower test room temperature, inducing more significant increase in FBF.
机译:目的:研究室温对健康人的手指血流量(FBF)变化的影响,这些健康人在不同室温下短期握住振动手柄。方法:每分钟结束时,用血流仪在六名男性受试者的三只手指的中指指骨背上进行一次测量,每分钟末一次,在暴露前的5分钟内,等时持续5分钟。振动手柄和正弦振动以及暴露后。产生的振动频率为125 Hz,均方根加速度为40 m / s(2)。在15 +/- 1、20 +/- 1、25 +/- 1和30 +/- 1摄氏度的四个室温下进行测量。结果:与握住振动手柄期间裸手的基线测量值相比在15 +/- 1摄氏度(P <0.001)和至少在30 +/- 1摄氏度(P <0.05)观察到最明显的FBF增加,振动后在25 +/- 1摄氏度观察到最小的FBF摄氏度(P <0.05)。在未暴露手的情况下,在振动过程中,在20 +/- 1摄氏度(P <0.01)和30 +/- 1摄氏度(P <0.01)时,仅在15 +/- 1摄氏度时FBF显着增加振动后为C(P <0.05)。结论:在不同的室温条件下,暴露和未暴露的手,由于握住振动手柄而导致的FBF响应与基线测量具有不同的模式,并且受室温影响。总体而言,在较低的测试室温下影响更大,从而导致FBF的增加幅度更大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号