In vivo evaluation of the iPex and Root ZX electronic apex locators using various irrigants

机译:使用各种冲洗液对iPex和Root ZX电子根尖定位器进行体内评估

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Aim: To evaluate in vivo the performance of the iPex and Root ZX electronic apex locators (EALs) in the presence of several irrigant solutions: 2.5% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). Methodology: Thirty-two single-rooted human teeth that were scheduled for extraction were selected. Teeth with metallic restorations, fractures, root resorption, pulp necrosis or open apices were not included The working length (WL) was determined electronically for the root canals with the iPex and Root ZX EALs in the presence of two different irrigant solutions, 2.5% NaOCl and 2% CHX. After the teeth had been extracted, a size 10 K-file was used to determine the reference working length (RWL), which was established at 0.5 mm short of the major foramen. In each case, the RWL was subtracted from the electronic measurements. Positive values indicated electronic measurements that exceeded the RWL (long measurements), whereas negative values indicated measurements that were short of the RWL. The values obtained with the different irrigants and EALs were compared using the paired t-test. Significance was set at P < 0.05. Results: The accuracy of the iPex nor Root ZX EAL was not affected by 2.5% NaOCl or 2% CHX (P > 0.05). However, significant differences were observed between the readings of the iPex and Root ZX, irrespective of whether 2.5% NaOCl or 2% CHX was used as the irrigant (P < 0.05). The iPex was less accurate than the Root ZX in determining the RWL. Conclusions: The accuracy of neither the iPex nor Root ZX EAL was affected by the irrigant used. However, the iPex was less accurate than the Root ZX in determining the RWL both for 2.5% NaOCl and for 2% CHX.
机译:目的:在存在以下几种冲洗液的情况下,评估iPex和Root ZX电子根尖定位器(EAL)的性能:2.5%的次氯酸钠(NaOCl)和2%的洗必太(CHX)。方法:选择了计划拔除的32颗单根人牙。不包括具有金属修复物,骨折,牙根吸收,牙髓坏死或开放性尖锐的牙齿。在存在两种不同的冲洗液,2.5%NaOCl的情况下,使用iPex和Root ZX EAL以电子方式确定牙根管的工作长度(WL)和2%CHX。拔出牙齿后,使用大小为10 K的锉刀确定参考工作长度(RWL),将其确定为距主要孔眼0.5毫米。在每种情况下,从电子测量值中减去RWL。正值表示超出RWL的电子测量值(长时间测量),而负值表示小于RWL的测量值。使用配对t检验比较使用不同灌溉液和EAL所获得的值。显着性设定为P <0.05。结果:iPex或Root ZX EAL的准确性不受2.5%NaOCl或2%CHX的影响(P> 0.05)。但是,无论使用2.5%NaOCl还是2%CHX作为冲洗液,iPex和Root ZX的读数之间都存在显着差异(P <0.05)。在确定RWL方面,iPex不如Root ZX准确。结论:iPex和Root ZX EAL的准确性均不受所用冲洗剂的影响。但是,在测定2.5%NaOCl和2%CHX的RWL方面,iPex不如Root ZX准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号