OBJECTIVE: To determine the bactericidal effect on surfaces of ceiling- and wall-mounted UV C (UVC) light (wavelength, 254 nm) in isolation units, compared with standard hospital environmental cleaning and chemical disinfection during final disinfection after patients are treated for infections. DESIGN: Microbial samples were obtained from surfaces in isolation units (patient room, anteroom, and bathroom) before and after irradiation with UVC, chloramine disinfection, and standard hospital environmental cleaning. Samples were tested using standard contact plates. SETTING: Four identical, negative air-pressure isolation units (patient room, anteroom, and bathroom) with a defined number of ceiling- and wall-mounted UVC light units. The UVC distribution was monitored in one isolation unit after irradiation for approximately 40 minutes, corresponding to doses ranging from 160 J/m2 in a shadowed area to 19,230 J/m2 at the mostly highly exposed site (which is high enough to inactivate most bacterial organisms, including spores). RESULTS: UVC disinfection significantly reduced the number of bacteria on surfaces directly or indirectly exposed to UVC to a very low number, as did 5% chloramine disinfection alone (P<.001 for both). Completely shadowed areas in the isolation unit (eg, the bed rail, lockers, and mattresses) still required disinfection by chemicals. CONCLUSION: Disinfection with UVC light may significantly reduce environmental bacterial contamination and thereby protect the next patient housed in an isolation room. UVC disinfection may not be used alone but is a good addition to chemical disinfection.
机译:目的:确定隔离单元中吊顶和壁挂式UV C(UVC)光(波长,254 nm)对表面的杀菌效果,并与患者接受感染治疗后的最终消毒过程中的标准医院环境清洁和化学消毒相比。设计:在紫外线消毒,氯胺消毒和标准医院环境清洁照射前后,从隔离单元(病房,前厅和浴室)的表面获取微生物样品。使用标准接触板测试样品。场所:四个相同的负压空气隔离装置(病房,前厅和浴室),带有定义数量的吸顶式和壁挂式UVC照明装置。辐照约40分钟后,在一个隔离单元中监测UVC分布,其剂量范围从阴影区域的160 J / m2到大部分高度暴露的部位的19,230 J / m2(足以使大多数细菌生物失活) ,包括孢子)。结果:UVC消毒显着减少了直接或间接暴露于UVC的表面上的细菌数量,将细菌数量降低到非常低的水平,单独使用5%的氯胺消毒也是如此(两者均P <.001)。隔离单元中完全阴影的区域(例如床栏,储物柜和床垫)仍需要用化学药品消毒。结论:用UVC光消毒可显着减少环境细菌污染,从而保护隔离房间中的下一位患者。 UVC消毒不能单独使用,而是化学消毒的良好补充。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号