Background. Needleless valve connectors for vascular catheters are widely used throughout the United States because they reduce the risk of biohazardous injuries from needlesticks and exposure to bloodborne pathogens, such as human immunodeficiency virus and hepatitis C virus. Patients with long-term central venous catheters are at significant risk of acquiring catheter-related bloodstream infections caused by microbes that gain access through the connection between the administration set and the catheter or an injection port. Most healthcare practitioners wipe the membranous septum of the needleless connector or the injection port with 70% alcohol before accessing it. We report a simulation study of the efficacy of conventional alcohol disinfection before access, compared with that of a novel antiseptic-barrier cap that, when threaded onto a needleless luer-activated valved connector, allows a chlorhexidine-impregnated sponge to come into continuous contact with the membranous surface; after removal of the cap, there is no need to disinfect the surface with alcohol before accessing it.Methods. One hundred five commercial, needleless luer-activated valved connectors, each accessible by a blunt male-connector luer-lock attachment, were purchased from 3 manufacturers and were tested. The membranous septum of each test device was first heavily contaminated with ~10(5) colony-forming units of Enterococcus faecalis and then was allowed to dry for 24 hours. Fifteen of the contaminated devices were not disinfected (positive controls), 30 were conventionally disinfected with a commercial 70% alcohol pledget, and 60 had the antiseptic cap threaded onto the connector and then removed after 10 minutes. The test connectors were then accessed with a sterile syringe containing nutrient broth media, which was injected, captured on the downstream side of the intraluminal fluid pathway, and cultured quantitatively.Results. All 15 control connectors (100%) showed massive transmission of microorganisms across the membranousseptum (4,500-10,000 colony-forming units). Of the 30 connectors accessed after conventional disinfection with 70% alcohol, 20 (67%) showed transmission of microorganisms (442-25,000 colony-forming units). In contrast, of the 60 connectors cultured after application of the novel antiseptic cap, only 1 (1.6%) showed any transmission of microorganisms (P<.001).Conclusions. The findings of this study show that, if the membranous septum of a needleless luer-activated connector is heavily contaminated, conventional disinfection with 70% alcohol does not reliably prevent entry of microorganisms. In contrast, the antiseptic-barrier cap provided a high level of protection, even in the presence of very heavy contamination. This novel technology deserves to be studied in a clinical trial.
机译:背景。用于血管导管的无针阀连接器在美国各地广泛使用,因为它们减少了针刺和接触人体免疫缺陷病毒和丙型肝炎病毒等血源性病原体造成生物危害的风险。长期使用中心静脉导管的患者极有可能获得由微生物引起的与导管相关的血液感染,这些微生物可通过给药装置与导管或注射端口之间的连接进入。大多数医疗从业人员在接触无针连接器或进样口的隔膜时,要用70%的酒精擦拭。我们报告了对进入前常规酒精消毒功效的模拟研究,与新型杀菌阻隔帽的仿真研究相比,该新型阻菌盖拧入无针鲁尔激活的带阀连接器时,可使氯己定浸渍的海绵持续接触膜状表面取下盖子后,无需在接触酒精之前用酒精对其进行消毒。从3家制造商处购买了一百五十五个商业用无针鲁尔阀驱动的带阀连接器,每个连接器都可以通过一个钝的阳连接器鲁尔锁附件进行访问。每个测试设备的膜状隔片首先被粪肠球菌的约10(5)个菌落形成单位严重污染,然后干燥24小时。 15个受污染的设备未经消毒(阳性对照),传统上用市售的70%酒精棉布消毒了30个,还有60个消毒帽拧在连接器上,然后在10分钟后取下。然后用装有营养肉汤培养基的无菌注射器接触测试连接器,将其注入,捕获在腔内流体路径的下游侧,并进行定量培养。所有15个对照连接器(100%)均显示出微生物跨膜隔膜(4,500-10,000个菌落形成单位)的大量传播。在用70%酒精进行常规消毒后访问的30个连接器中,有20个(67%)显示出微生物的传播(442-25,000个菌落形成单位)。相反,在使用新型消毒帽后培养的60个连接器中,只有1个(1.6%)显示出任何微生物传播(P <.001)。这项研究的结果表明,如果无针路厄氏激活连接器的膜间隔受到严重污染,常规的70%酒精消毒不能可靠地阻止微生物进入。相比之下,即使在污染非常严重的情况下,抗菌阻隔帽也能提供高水平的保护。这项新技术值得在临床试验中进行研究。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号