ZIL is operating a dryer supplied by M/s TEC of Japan enclosed in their NPK plant for 30 years.The dryer having welded tyre construction failed prematurely and the same was changed over to loose ring type tyre support.Over the years due to corrosion and ageing,cracking of the dryer shell were encountered,predominantly at the centre and other locations.Initially,it was decided to replace the dryer with a new shell as the shell plate has thinned down drastically from 16mm to as low as 8mm at certain sections.However,due to high erection time of 60 to 65 days,it was decided to increase the service life of the dryer by another 3 to 5 years by reinforcement.Hence,in 1997 ZIL design modifications were carried out and other teething problems were sold.The modified dryer performed well till 2003.Meanwhile,various modifications were carried out to increase the capacity of the plant which put additional load on the dryer leading to bending stress on the middle of the dryer which caused periodic cracks in that zone .It was again decided to further reinforce the dryer so that the life can be extended by another 2 years,which will be adequate to replace the dryer with a new larger dryers to take care of the increased production.The reinforcement of the dryer was carried out in-house.The dryer has operated one year without any down time due to the shell cracking at the middle zone and still in operation and expected to be replaced by a new one in the first quarter of 2006.The article gives details of the modifications carried out to reinforce the dryer in 1997 and last year.
机译:ZIL使用由日本M / s TEC在其NPK工厂封闭的干燥机运行了30年,该干燥机由于焊接轮胎构造而过早失效,后来由于腐蚀和腐蚀而被更换为松散的环形轮胎支撑。干燥器的外壳经常老化,破裂,主要发生在中央和其他位置。起初,决定更换新的干燥器,因为在某些部分,外壳板的厚度从16mm急剧减小至8mm。然而,由于60至65天的高架设时间,决定通过加固将干衣机的使用寿命再延长3至5年。因此,1997年对ZIL进行了设计修改,并解决了其他长牙问题。改型的干燥机运行良好,直到2003年。同时,进行了各种改型以增加工厂的生产能力,这给干燥机增加了额外的负载,从而导致干燥机中间出现弯曲应力,从而导致周期性再次决定进一步加强干燥机,以便将寿命再延长2年,这足以用新的更大的干燥机替换干燥机,以照顾增加的产量。该干燥机在内部运行。由于中间区域的外壳破裂,该干燥机已经运行了一年,没有任何停机时间,并且仍在运行,预计在2006年第一季度将被替换为新的干燥机。详细介绍了为加强干燥机而在1997年和去年进行的修改。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号