Oxygen mask fit analysis in F-16 fighter pilots using 3D imaging

机译:使用3D成像的F-16战斗机飞行员氧气面罩贴合度分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Background: The majority of Dutch F-16 pilots experience in-flight oxygen mask related nasal discomfort and injury. We aimed to analyze the fit of the oxygen mask. Methods: We successfully scanned 35 pilots with a 3D scanner to measure the distance between the contact area on the nose and the oxygen mask in seven points, and the difference (Δ) in angle between the nose and the mask relative to the facial midline. Ill fit was defined as ≥ 4 mm distance, or Δ ≥ 4o angle. Intraclass correlation coefficients were used to objectify the reproducibility of the measurements. Results: There were 35 pilots who had ≥ 4 mm distance between the nasal dorsum and the mask and 14 pilots had Δ ≥ 4o angle. Reproducibility of the distance measurements was excellent (R ≥ 0.93, CI 95% 0.86-0.96) and of the angle measurements was good (R = 0.72, CI 95% 0.5-0.8). Conclusion: The room for displacement that we found may be a contributor to the discomfort. It is indicative of an ill fit of the oxygen mask, since all subjects had complaints. We recommend evaluating whether improved fixation of the mask and simultaneous reduction of the pressure on the nose will improve comfort.
机译:背景:大多数荷兰F-16飞行员都会遇到机上氧气面罩引起的鼻部不适和伤害。我们旨在分析氧气面罩的适合性。方法:我们成功地使用3D扫描仪扫描了35名飞行员,以测量鼻子与氧气面罩之间的接触区域之间的距离(共7个点),以及鼻子和面罩相对于面部中线的角度差(Δ)。不适度定义为距离≥4 mm,或Δ≥4o。类内相关系数用于客观化测量结果的可重复性。结果:35名飞行员的鼻背与面罩之间的距离≥4 mm,14名飞行员的Δ≥4o角。距离测量的可重复性极佳(R≥0.93,CI 95%0.86-0.96),角度测量的重复性良好(R = 0.72,CI 95%0.5-0.8)。结论:我们发现的移位空间可能是造成不适的原因。这表明氧气面罩不合适,因为所有受试者都有不适。我们建议评估改善面罩的固定性并同时降低鼻子上的压力是否会改善舒适度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号