The paper describes the results of metallographic, tribological, and microscopic tests of wire connectors. It was shown that the structure and thickness of the tin layer on the copper element varies greatly. The paper describes the results of tribological investigations for electrical connectors in the initial state and covered with a layer of oxides formed as a result of corrosion. The results of tribological tests have shown a great influence of the oxide layer on friction and wear of tin coatings. The results of friction factor measurements were confirmed by microscopic observations. The tests confirmed that the oxide layer reduces plastic deformation of the tin coating and limits its tribological wear. Due to the brittleness and low adhesion of the oxide layer, friction-induced chipping was observed.