首页> 外文期刊>Athletic therapy today : >Reliability of a Modified Active Knee Extension Test for Assessment of Hamstring Flexibility
【24h】

Reliability of a Modified Active Knee Extension Test for Assessment of Hamstring Flexibility

机译:改良的主动式膝关节伸展试验用于评估Ham绳韧度的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Context: Hamstring injuries are prevalent among team and field sport athletes, and poor flexibility has been theorized as a risk factor. The active knee extension test has been proposed as the gold standard for assessment of hamstring flexibility. Many variations of this test are employed, each of which utilizes a complex apparatus that is difficult to transport, time-consuming to set up, and often unavailable to most clinicians. Thus, a method that utilizes inexpensive and readily available equipment is needed for screening. Objective: To establish the intertester and intratester reliability of a modified active knee extension test that requires minimal equipment. Design: Reliability study. Setting: Athletic therapy facilities. Patients or Other Participants: Fifteen male athletes (19.5 ± 0.6 years) free from any orthopedic or neurological disorders were recruited from a convenience sample of collegiate students. Intervention(s): Three testers participated in three training sessions before data collection. Participants completed three trials of the modified active knee extension test and returned the following week at the same time and day to repeat the process. Main Outcome Measure(s): The intraclass correlation coefficient (ICC), 95 % confidence interval, and the standard error of measurement were calculated to assess inter- and intratester reliability. Results: High ICC values were found for intertester reliability (right leg = .98; left leg = .99) and intratester reliability (right leg = .78-.89; left leg = .79-.94). Conclusions: The modified active knee extension test utilizes readily available equipment and offers a quick, reliable, and low-cost alternative for measurement of hamstring flexibility.
机译:背景:Ham绳肌损伤在团体和田径运动运动员中普遍存在,而柔韧性差被认为是危险因素。主动膝关节伸展试验已被提议作为评估绳肌柔韧性的金标准。使用了该测试的许多变体,每种变体都使用复杂的设备,该设备难以运输,设置耗时且通常对于大多数临床医生而言是不可用的。因此,需要一种利用廉价且容易获得的设备进行筛选的方法。目的:建立需要最少设备的改良型主动式膝关节伸展试验的测试者间和测试者间可靠性。设计:可靠性研究。地点:运动治疗设施。患者或其他参与者:从便利的大学生样本中招募了15名无任何骨科或神经系统疾病的男运动员(19.5±0.6岁)。干预措施:在收集数据之前,三名测试人员参加了三期培训课程。参加者完成了改良的主动式膝关节伸展试验的三项试验,并于下一周的同一时间和同一天返回以重复该过程。主要观察指标:计算组内相关系数(ICC),95%置信区间和标准误差,以评估测试者之间和测试者之间的可靠性。结果:发现测试者间可靠性(右腿= .98;左腿= .99)和测试者内部可靠性(右腿= .78-.89;左腿= .79-.94)的ICC值较高。结论:改良的主动式膝关节伸展试验利用了现成的设备,为测量绳肌的柔韧性提供了一种快速,可靠和低成本的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号