首页> 外文期刊>Atmospheric Measurement Techniques >Recent divergences in stratospheric water vapor measurements by frost point hygrometers and the Aura Microwave Limb Sounder
【24h】

Recent divergences in stratospheric water vapor measurements by frost point hygrometers and the Aura Microwave Limb Sounder

机译:霜点湿度计和Aura微波肢体测深仪在平流层水汽测量中的最新分歧

获取原文
获取原文并翻译 | 示例
       

摘要

Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0 degrees-N); Hilo, Hawaii (19.7 degrees-N); and Lauder, New Zealand (45.0 degrees-S) - from August 2004 through December 2012 not only demonstrated agreement better than 1-% between 68 and 26-hPa but also exposed statistically significant biases of 2 to 10-% at 83 and 100-hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2 degrees-N), and San Jos,, Costa Rica (10.0 degrees-N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year(-1) (0.6 to 1.5-% year(-1)) from similar to 2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980-2010) average growth rate of stratospheric water vapor (similar to 1-% year(-1)) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP-MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements.
机译:气球式霜点湿度计(FPs)和Aura微波肢体测深仪(MLS)可提供对流层和平流层下部(UTLS)中水蒸气的高质量垂直剖面测量。先前比较了FPs和MLS在三个地点(科罗拉多州博尔德(北纬40.0度))平流层水汽测量结果;夏威夷希洛(北纬19.7度);和新西兰劳德(45.0度南)-从2004年8月到2012年12月,不仅显示在68至26-hPa之间的一致性好于1-%,而且在83至100-pa时也显示出2-10%的统计学显着偏差hPa(Hurst et al。,2014)。 FP-MLS差异的简单线性回归分析显示,两种仪器之间没有明显的长期漂移。在这里,我们将漂移比较扩展到2015年中期,并添加了两个FP站点-德国Lindenberg(北纬52.2度)和哥斯达黎加San Jos(北纬10.0度),它们使用了不同制造和校准功能的FP。水蒸气的声音。延长的比较期表明,在五个站点中,四个站点的平流层FP和MLS测量值与2010年相似至2006年中中期之间的差异为0.03至0.07 ppmv年(-1)(0.6至1.5 %%(-1))。 2015年。这些速率的大小与FP在Boulder上测得的平流层水汽30年平均增长率(1980-2010年)(近似于1-%year(-1))相似(Hurst等,2011)。到2015年年中,某些站点的FP-MLS差异大到足以超过FP和MLS测量结果的组合精度估计值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号