A Flow Sensor Suitable for Use With Split-flow Ventilation-First Preclinical Data.

机译:一种流量传感器,适合与分流通风优先临床前数据配合使用。

获取原文
获取原文并翻译 | 示例
       

摘要

Volutrauma caused by artificial ventilation represents a major morbidity risk for premature infants. Our working group has recently developed an innovative "split-flow ventilation" system aiming at the reduction of tidal volumes (TVs). The main problem for the practical use of this system is the fact that conventional measurements of commercially available flow sensors are distorted by the split flow. In this study, we present the first preclinical data from testing an adapted flow sensor combination recognizing the split flow. A preterm infant test lung was conventionally ventilated, modified by insertion of a split-flow line. In addition to the customary flow sensor (FS-1), a second flow sensor (FS-2) was integrated into the split-flow line, and a third (FS-3) was placed at the exit of the test lung for reference measurements. The signals of all three flow sensors were read and processed by a computer. The program was set to graphically add up flow curves 1, 2, and 3 during one ventilation loop. After 10 runs, a mean curve of FS-1+2 was calculated and compared to the mean curve of FS-3. Furthermore, the mean TV of 10 runs measured by FS-1+2 was calculated and compared with the mean TV calculated by FS-3. The summation curve FS-1+2 proved identical to the reference curve FS-3. FS-1+2 yielded a TV of 6.6 +/- 0.01 mL (inspiratory) and 6.7 +/- 0.02 mL (expiratory). The corresponding values of FS-3 were 6.5 +/- 0.20 mL and 6.6 +/- 0.09 mL, respectively. According to our results, the presented flow sensor constellation allows exact flow measurements in the experimental setting and appears suitable for usage in a split-flow ventilation circuit under clinical conditions.
机译:人工通气引起的Volutrauma代表了早产婴儿的主要发病风险。我们的工作组最近开发了一种创新的“分流通风”系统,旨在减少潮气量(TV)。该系统的实际使用的主要问题是以下事实:市售流量传感器的常规测量值因分流而失真。在这项研究中,我们提供了通过测试可识别分流的适应性流量传感器组合而获得的首个临床前数据。常规上对早产儿测试肺进行通气,通过插入分流管进行改良。除常规流量传感器(FS-1)之外,第二个流量传感器(FS-2)集成到分流管线中,第三个流量传感器(FS-3)放置在测试肺的出口以供参考测量。所有三个流量传感器的信号均由计算机读取和处理。该程序设置为以图形方式在一个通风循环中将流量曲线1、2和3相加。运行10次后,计算FS-1 + 2的平均曲线,并将其与FS-3的平均曲线进行比较。此外,计算了通过FS-1 + 2测量的10次运行的平均电视,并将其与通过FS-3计算的平均电视进行比较。求和曲线FS-1 + 2与参考曲线FS-3相同。 FS-1 + 2产生的TV为6.6 +/- 0.01 mL(吸气)和6.7 +/- 0.02 mL(呼气)。 FS-3的相应值分别为6.5 +/- 0.20 mL和6.6 +/- 0.09 mL。根据我们的结果,提出的流量传感器星座图可以在实验环境中进行精确的流量测量,并且似乎适合在临床条件下用于分流通风回路中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号