Problem statement: The aim of this research was to optimize the performance of solenoid valve used in Variable Rate Application System (VRA) in term of time response. The overall time response is usually divided into four parts i.e., plunger opening time, pressure opening time, plunger closing time and pressure closing time. Approach: The performance and design of the a solenoid valve used in VRA was analyzed methematically and experimentally. Voltage, current, pressure, spring constant, flow rate and mass of the plunger were found to be the main parameters affecting the performance of solenoid valve. Based on the analyses, some modifications were introduced in the design of the solenoid valve to enhance its performance. The newly designed solenoid valve was tested by varying the main parameters and its performance was compared in terms of time response. Results: The time respnose of the modified valve showed improvement. The plunger closing time for the modified valve improved by 79%. Depending on the types of nozzle, the pressure opening and closing time responses were reduced by 37-53% and 55-73% respectively. It was also observed time response was improved by 34% when springs with lower spring constants are used. Conclusion: After thorough testing of both the original and proposed valves, it was observed that proposed valve average performance is faster than the original valve by 22 msec or 56%. However, it was also found that it is mandatory to increase the operating voltage of propsed valve for the better performance.
机译:问题陈述:这项研究的目的是在时间响应方面优化可变速率应用系统(VRA)中使用的电磁阀的性能。总的时间响应通常分为四个部分,即,柱塞打开时间,压力打开时间,柱塞关闭时间和压力关闭时间。方法:对VRA中使用的电磁阀的性能和设计进行了数学和实验分析。发现电压,电流,压力,弹簧常数,柱塞的流量和质量是影响电磁阀性能的主要参数。在分析的基础上,对电磁阀的设计进行了一些修改以增强其性能。通过改变主要参数对新设计的电磁阀进行了测试,并在时间响应方面比较了其性能。结果:改进的瓣膜的时间响应显示出改善。改进型阀的柱塞关闭时间缩短了79%。根据喷嘴的类型,压力打开和关闭时间响应分别降低了37-53%和55-73%。还观察到,当使用弹簧常数较低的弹簧时,时间响应提高了34%。结论:在对原始阀和建议阀进行全面测试后,发现建议阀的平均性能比原始阀快22毫秒或56%。但是,还发现必须提高辅助阀的工作电压才能获得更好的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号