INTRODUCTION: Intramedullary nailing has become a popular and effective procedure for the treatment of most fractures of the tibial diaphysis. However, distal interlocking screw placement under fluoroscopic control is responsible for the majority of the radiation exposure and a significant loss of surgical time in the entire nailing procedure. To limit fluoroscopy use, during distal interlocking screw placement, Orthofix((R)) has developed a distal targeting device which compensates for the inevitable deformation of the nail in the sagittal plane during its insertion. This prospective clinical study evaluates the efficacy of this distal targeting device for distal locking. MATERIALS AND METHODS: One hundred and fifteen fresh tibial fractures in the same number of patients with a mean age of 37.5 years (17-85 years) were treated with operative stabilization using the Orthofix tibial nailing system. RESULTS: The mean duration of the operation was 38 min (20-55 min). A mean of four intra-operative plain X-rays (2-6 X-rays) were used in 103 cases to confirm guide wire placement, final nail insertion and accuracy of screws placement. The mean duration of the use of the image intensifier utilized in the remaining 12 fractures was 5 s (3-8 s). The distal targeting device failed in 12 (5.2%) distal locking screws. CONCLUSION: This study demonstrates that distal locking can be performed easily and successfully with minimal exposure to radiation, once the surgeon develops a reasonable experience with the use of this distal targeting device.
机译:简介:髓内钉治疗已成为治疗大多数胫骨干physi端骨折的流行且有效的方法。然而,在荧光镜控制下远侧联锁螺钉的放置是造成大部分放射线暴露的原因,并且在整个钉扎过程中大量浪费了手术时间。为了限制荧光检查的使用,在远侧互锁螺钉放置期间,Orthofix(R)开发了一种远侧靶向装置,该装置可补偿在插入过程中指甲在矢状平面内不可避免的变形。这项前瞻性临床研究评估了这种远端靶向装置对远端锁定的功效。材料与方法:使用Orthofix胫骨钉系统对手术切除的115例平均年龄37.5岁(17-85岁)的胫骨新鲜骨折进行手术固定。结果:平均手术时间为38分钟(20-55分钟)。在103例病例中,平均进行了4次术中X线平片检查(2-6次X线检查),以确认导丝的放置,最终钉子的插入和螺钉放置的准确性。在其余12个骨折中使用图像增强器的平均持续时间为5 s(3-8 s)。远端靶向设备的12个(5.2%)远端锁定螺钉失效。结论:这项研究表明,一旦外科医生使用该远端靶向装置获得了合理的经验,就可以轻松,成功地进行远端锁定,而放射线的暴露最少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号