Measuring methods for functional reach test: comparison of 1-arm reach and 2-arm reach.

机译:功能伸手可及性测试的测量方法:一臂伸和二臂伸比较。

获取原文
获取原文并翻译 | 示例
       

摘要

Kage H, Okuda M, Nakamura I, Kunitsugu I, Sugiyama S, Hobara T. Measuring methods for functional reach test: comparison of 1-arm reach and 2-arm reach. OBJECTIVES: To investigate which functional reach test better reflects the center of pressure excursion, a 1-arm reach or a 2-arm reach, and to investigate the effect of trunk rotation on the reach distance in a 1-arm reach. In addition, we considered the influence of the individual variation at the starting position. DESIGN: Descriptive study using a force platform and a 3-dimensional (3D) motion capture system. SETTING: Motion analysis laboratory in a college setting. PARTICIPANTS: Elderly volunteers (N=41; 15 men, 26 women; 71.8+/-5.2y). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: 3D coordinate data and the movement of the center of pressure. RESULTS: The correlation between the reach distance and the center of pressure excursion was significantly higher (P<.05) for the 1-arm reach (r=.60, .72) compared with a 2-arm reach (r=.41, .55). In the case of the 1-arm reach, center of pressure excursion was a significant factor affecting reach distance (beta=.319, .470) in multivariate regression analysis, but trunk rotation was not (beta=.162, .095). When the reach distance was measured using the heel as a reference, the correlation was stronger. CONCLUSIONS: To evaluate dynamic balance, a 1-arm reach, which better reflects center of pressure excursion, is more valid. It is meaningful to reduce the individual variation of the acromion at the starting position.
机译:Kage H,Okuda M,Nakamura I,Kunitsugu I,Sugiyama S,HobaraT。功能触及率测试的测量方法:1臂触及2臂触及的比较。目的:调查哪种功能伸手可及的距离测试可以更好地反映压力偏移的中心,1臂伸直或2臂伸直的中心,并研究躯干旋转对1臂伸直中的伸直距离的影响。另外,我们考虑了起始位置上个体变化的影响。设计:使用力平台和3维(3D)运动捕捉系统进行描述性研究。地点:大学环境下的运动分析实验室。参与者:老年志愿者(N = 41; 15名男性,26名女性; 71.8 +/- 5.2y)。干预措施:不适用。主要观察指标:3D坐标数据和压力中心的运动。结果:1臂伸直距离(r = .60,.72)与2臂伸直距离(r = .41)的触及距离和压力偏移中心之间的相关性显着更高(P <.05)。 ,.55)。在单臂到达的情况下,压力偏移中心是影响到达距离的重要因素(β= .319,.470),但在多元回归分析中,躯干旋转没有影响(β= .162,.095)。当以脚后跟为基准测量触及距离时,相关性更强。结论:为了评估动态平衡,可以更好地反映压力偏移中心的1臂触及范围更有效。减少肩峰在起始位置的个体变化是有意义的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号