WAMS - based control of series FACTS devices installed in tie-lines of interconnected power system

机译:基于WAMS的对互连电力系统联络线上安装的FACTS系列设备的控制

获取原文
获取原文并翻译 | 示例
       

摘要

This paper addresses the state-variable stabilising control of the power system using such series FACTS devices as TCPAR installed in the tie-line connecting control areas in an interconnected power system. This stabilising control is activated in the transient state and is supplementary with respect to the main steady-state control designed for power flow regulation. Stabilising control laws, proposed in this paper, have been derived for a linear multi-machine system model using direct Lyapunov method with the aim to maximise the rate of energy dissipation during power swings and therefore maximisation their damping. The proposed control strategy is executed by a multi-loop controller with frequency deviations in all control areas used as the input signals. Validity of the proposed state-variable control has been confirmed by modal analysis and by computer simulation for a multi-machine test system.
机译:本文讨论了使用串联FACTS设备(如安装在互连电力系统的联络线连接控制区域中的TCPAR)这样的FACTS系列设备对电力系统进行状态可变的稳定控制。该稳定控制在瞬态中被激活,并且相对于设计用于潮流调节的主要稳态控制是补充。本文提出的稳定控制定律是使用直接Lyapunov方法推导的线性多机系统模型的,其目的是最大化功率摆幅期间的能量耗散率,从而最大化其阻尼。所提出的控制策略是由多回路控制器执行的,其中所有控制区域的频率偏差都用作输入信号。通过模态分析和多机测试系统的计算机仿真,已经证实了所提出的状态变量控制的有效性。