Keeping it Simple Balloon Devices for Atrial Fibrillation Ablation Therapy

机译:保持简单的气球设备心房纤维性颤动消融治疗

获取原文
获取原文并翻译 | 示例
           

摘要

Atrial fibrillation is a common disease of increasing prevalence. Catheter ablation has evolved into an established therapeutic option that mainly aims to electrically isolate the pulmonary veins from atrial myocardium. The traditional method comprises point-by-point radiofrequency current ablation guided by electroanatomical mapping and has proven to be effective and safe in experienced hands. However, this approach is technically highly demanding and associated with a long learning curve, limiting its widespread utilization. To address these shortcomings, simplified ablation toots for pulmonary vein isolation are needed. In this context, balloon devices promise to ease the procedure by approaching the entire orifice of a targeted pulmonary vein in a single maneuver. This requires less catheter manipulation in the left atrium and often allows ablation of a large volume of tissue with a single application of ablative energy. Two balloon devices- one using cryoenergy, the other laser energy-have already been established in clinical routine and have demonstrated noninferiority when compared with radiofrequency ablation in large randomized trials. More balloon devices are on the verge of being introduced into clinical practice and bear the potential to expand the interventional electrophysiotogist's armamentarium when treating atrial fibrillation. The authors review the use of the established balloon devices available for atrial fibrillation ablation and provide a detailed outlook on upcoming balloon technologies, including 3 different balloons utilizing radiofrequency energy as well as a novel cryoballoon. (C) 2020 by the American College of Cardiology Foundation.
机译:心房颤动是一种常见的疾病增加患病率。演变成一个确定的治疗选择主要的目标是电隔离从心房心肌肺静脉。传统方法包括逐点详述的射频电流消融的指导下中华映射和已被证明是有效和安全的在经验丰富的手中。这种方法在技术上是高度要求相关的学习曲线,限制其广泛的利用。缺点,简化消融亲密的人肺静脉隔离是必要的。背景下,气球设备承诺缓解过程的接近整个孔有针对性的肺静脉在一个回旋余地。这需要更少的导管的操作左心房,通常允许消融的体积与单个应用程序的组织烧蚀能量。cryoenergy,其他激光协助产生了成立于临床常规和证明了相比,非劣性在大型随机射频消融术试用被引入临床实践和熊可能扩大介入electrophysiotogist当治疗的医疗设备心房纤颤。建立了气球的设备可用房颤消融和提供详细的展望即将到来的气球技术,包括三种不同的气球利用射频能量以及小说cryoballoon。心脏病学会的基础。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号