首页> 外文期刊>Applied occupational and environmental hygiene >Evaluation of the SureSpot direct-reading instrument for the determination of polymeric MDI aerosols.
【24h】

Evaluation of the SureSpot direct-reading instrument for the determination of polymeric MDI aerosols.

机译:对SureSpot直读仪器进行测定以测定聚合MDI气溶胶的评估。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Recent studies in our laboratories have focused on the reliability of direct-reading instruments for the determination of airborne isocyanate concentrations. The evaluation of airborne isocyanates is complicated because these substances exist as diisocyanate monomers and polyisocyanate oligomers, both in the vapor and aerosol phases. The studies showed that a number of direct-reading instruments, including the SureSpot test kit, do not allow an accurate determination of isocyanates in the aerosol phase. Using a test chamber, concentrations of various commercial polymeric methylenediphenyl diisocyanates (PMDI) were generated in the aerosol phase to examine the correlation between the SureSpot monitor and two laboratory methods. The results obtained with the SureSpot and laboratory methods correlated poorly. More precisely, the results indicated that the SureSpot direct-reading instrument had a distinctive response to each commercial PMDI and, in addition, it was not accurate for the determination of total PMDI in the aerosol phase. It seemed that the analytical response of the SureSpot is based on a calibration curve only reliable for MDI and not for the determination of PMDIs in the aerosol phase. Further investigation also indicated that the calibration provided by the manufacturer could not be converted into a linear curve over the suggested MDI concentrations range. An appropriate calibration procedure was developed in our laboratories for the SureSpot to accurately determine all commercial PMDIs without great variability.
机译:我们实验室中的最新研究集中于直接读取仪器测定空气中异氰酸酯浓度的可靠性。空气中异氰酸酯的评估很复杂,因为这些物质在汽相和气溶胶相中均以二异氰酸酯单体和多异氰酸酯低聚物的形式存在。研究表明,包括SureSpot测试试剂盒在内的许多直接读取仪器都无法准确测定气溶胶相中的异氰酸酯。使用测试室,在气溶胶相中产生了各种商业聚合的亚甲基二苯基二异氰酸酯(PMDI)浓度,以检查SureSpot监测器与两种实验室方法之间的相关性。用SureSpot和实验室方法获得的结果相关性很差。更准确地说,结果表明SureSpot直读仪器对每种商业PMDI都有独特的响应,此外,它对于确定气溶胶相中的总PMDI也不准确。看来,SureSpot的分析响应基于校准曲线,该校准曲线仅对MDI可靠,而对于气溶胶相中的PMDI却不可靠。进一步的研究还表明,制造商提供的校准不能在建议的MDI浓度范围内转换为线性曲线。在我们的实验室中,针对SureSpot开发了适当的校准程序,以准确地确定所有商业PMDI,而没有很大的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号