This study aimed to validate finite element analysis (FEA) estimation of strength, identify high-resolution peripheral quantitative computed tomography (HR-pQCT) measures correlating with strength, and evaluate the precision of HR-pQCT measurements to longitudinally monitor effects of osteoporosis treatment in ovariectomized (OVX) non-human primates (NHPs). HR-pQCT images were acquired in three groups of NHPs: Intact (n=10), OVX-odanacatib treated (OVX-ODN 30mg/kg, n=10) and OVX-vehicle treated (OVX-Veh, n=10) at the ultradistal (UD) and distal 1/3 radii and tibia at 12, 16 and 20months. FEA estimates of bone strength using the Pistoia criterion were validated by ex-vivo mechanical compression (r 2=0.95) of the UD radius. Single linear regressions of FEA-determined ultimate stress showed high correlation with HR-pQCT derived parameters: integral vBMD (r 2=0.86), bone volume fraction (r 2=0.84) and cortical thickness (r 2=0.79). Precision of HR-pQCT measurements, obtained from an excised radius and tibia, showed low variation (CV=0.005%-5.6%) and helped identify possible sources of error. Comparison of OVX-Veh and Intact groups showed decreases in bone parameters demonstrating trends consistent with bone loss. Comparison of OVX-ODN and OVX-Veh groups showed a treatment effect with increases in bone parameters: integral vBMD (477±27 vs. 364±22mgHA/cm 3) and cortical thickness (Ct.Th) (0.90±0.07 vs. 0.64±0.04mm) at the UD radius, Ct.Th (2.15±0.28 vs. 1.56±0.08mm) at the distal 1/3 radius. Axial compression peak stress calculated and obtained experimentally showed the OVX-ODN group was 33% stronger than the OVX-Veh group. We conclude that HR-pQCT and FEA serve as robust techniques to longitudinally monitor bone parameters and strength in NHP's.
机译:这项研究旨在验证强度的有限元分析(FEA)估计,确定与强度相关的高分辨率外周定量计算机体层摄影(HR-pQCT)措施以及评估HR-pQCT测量的准确性以纵向监测骨质疏松症治疗的效果去卵巢(OVX)非人类灵长类动物(NHP)。在三组NHP中获取HR-pQCT图像:完整的(n = 10),OVX-odanacatib处理的(OVX-ODN 30mg / kg,n = 10)和OVX-车辆处理的(OVX-Veh,n = 10)。在12、16和20个月时的超远距(UD)和远端1/3半径和胫骨。通过Pistoia准则对骨强度的FEA估计通过UD半径的离体机械压缩(r 2 = 0.95)进行了验证。 FEA确定的最终应力的单线性回归显示与HR-pQCT派生的参数高度相关:积分vBMD(r 2 = 0.86),骨体积分数(r 2 = 0.84)和皮质厚度(r 2 = 0.79)。从切除的radius骨和胫骨获得的HR-pQCT测量精度显示出较低的变化(CV = 0.005%-5.6%),有助于确定可能的误差来源。 OVX-Veh组和完整组的比较显示,骨参数降低,表明与骨丢失一致的趋势。 OVX-ODN和OVX-Veh组的比较显示治疗效果随骨参数的增加:整体vBMD(477±27 vs. 364±22mgHA / cm 3)和皮质厚度(Ct.Th)(0.90±0.07 vs. 0.64) UD半径处为±0.04mm),远端1/3半径处为Ct.Th(2.15±0.28 vs.1.56±0.08mm)。计算并通过实验获得的轴向压缩峰值应力表明,OVX-ODN组比OVX-Veh组强33%。我们得出结论,HR-pQCT和FEA可以作为可靠的技术来纵向监测NHP的骨参数和强度。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号