首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >Doppler broadening effect on low-energy photon dose calculations using MCNP5 and PENELOPE.
【24h】

Doppler broadening effect on low-energy photon dose calculations using MCNP5 and PENELOPE.

机译:多普勒展宽效应对低能量光子剂量计算使用MCNP5和佩内洛普。

获取原文
获取原文并翻译 | 示例
           

摘要

Recent releases of the MCNP5 and PENELOPE Monte Carlo codes include the transport algorithm and momentum profiles that are necessary for accounting for Doppler broadening in Compton scattering processes. Such improvements might be particularly important in low-energy photon dose calculations. MCPLIB04 and PENDBASE (PENELOPE photon dataset) are based on the EPDL97 library with Compton momentum profiles, while MCPLIB03 and MCPLIB02 are based on the 1970's old library, with MCPLIB03 including the Compton momentum profiles. To isolate the dosimetric effects of Doppler broadening by the transport algorithm and Compton momentum profiles, we varied the choice of the above photon databases, in the same simulation geometry, using either version of MCNP5 or MCNP4 (no Doppler algorithm). We computed dose rate constants and dose distributions for r = 0.2-10 cm from a point source in a 50-cm-diameter sphere of water. Nine discrete energies for primary photon sources were chosen in the range of 10-150 keV. The results from both versions of MCNP with MCPLIB04 agreed with those of PENELOPE within statistical uncertainties (+/-1%) over the entire ranges of energies and radial distances investigated. MCNP5 with either MCPLIB03 or MCPLIB02 yielded almost identical data within statistical uncertainties (+/-1%) over the entire ranges of energies and radial distances investigated. This implies that in spite of the spectral broadening of scattered photons due to the orbital electron motion, the dosimetric effect of Doppler broadening for Compton interactions in water appears to be insignificant in the energy range investigated. The spectral dose analysis with and without the Doppler broadening supported this conclusion.
机译:最近版本的MCNP5和佩内洛普·蒙特卡洛代码包括传输算法动力配置文件是必要的在康普顿占多普勒展宽散射过程。特别重要的低能光子剂量计算。光子的数据集)是基于EPDL97库康普顿动力配置文件,而MCPLIB03和MCPLIB02是基于1970年的老图书馆,MCPLIB03包括康普顿势头配置文件。由传输算法和多普勒展宽康普顿动力配置文件,我们不同的选择上面的光子数据库,在相同的几何仿真,使用的版本MCNP5或MCNP4(无多普勒算法)。剂量计算速率常数和剂量分布为r = 0.2 -10厘米50-cm-diameter球体的水源。离散光子能量的主要来源选择在10 - 150 keV的范围。从两个版本的MCNP MCPLIB04同意了在统计与佩内洛普不确定性(+ / - -1%)的整个范围能量和径向距离调查。MCPLIB03或MCPLIB02几乎相同的数据在统计的不确定性(+ / - -1%)在整个范围的能量径向距离调查。尽管光谱展宽的分散光子由于轨道电子的运动,多普勒展宽的剂量测定的影响在水里似乎康普顿交互无关紧要的能量范围调查。光谱剂量分析有或没有多普勒展宽支持这个结论。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号