For the measurement of impulsive currents, which might occur in cases of electromagnetic interference, for example currents generated by the non-linear behavior of electronic appliances, a wide-band large dynamic range current transducer is needed. The electrical response of such a transducer is determined using conventional techniques, that use frequency sweeps of sinusoidal continuous wave signals. For non-linear and/or time invariant systems the superposition of continuous wave signals of multiple frequencies might not be equal to an impulsive current, which is representative for the actual measured signals, and is therefore of interest. In this letter the electrical response of current transducers is determined using impulsive signals, and compared to continuous wave tests. Time domain parameters such as rise time and peak amplitude are extracted, and the frequency response is analyzed using a Fourier transform. The experiments show that the impulsive test is in agreement with the continuous wave method and provides a good alternative method. A combination of impulses could cover a large bandwidth, and is a fast and cost effective approach.
机译:测量的脉冲电流,可能发生的情况下的电磁干扰,例如电流产生的电子电器的非线性行为一个宽带大动态范围电流传感器是必要的。这种传感器使用决定传统的技术,使用频率清洁工的正弦连续波信号。非线性和/或时不变系统连续波信号的叠加多个频率可能不等于一个脉冲电流,也就是代表实际的测量信号,因此的兴趣。电流传感器使用决定脉冲信号,并通过比较连续波测试。时间和峰值振幅提取,使用傅里叶频率响应进行了分析变换。脉冲测试协议连续波方法,提供了一个很好的替代方法。可以覆盖很大的带宽,是一个快速和成本效益的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号