The concentrations of Tc-99 and impurity radionuclides in the Tc-99m tracer solution obtained from a commercial Mo-99/Tc-99m generator were measured by gamma spectrometry and liquid scintillation counting. Mo-99 and Ru-103 were found in the Tc-99m eluate. A simple separation using two extra alumina cartridges was investigated to purify the eluate to obtain a suitable Tc-99m tracer with low Tc-99 concentration. The activity ratio of Tc-99/Tc-99m in the prepared Tc-99m solution is lower than 15 x 10(-9), which is higher than the theoretical ratio of less than 10 x 10(-9). The possible reason is discussed. The Tc-99 in the 20 kBq spiked Tc-99m tracer was found to be less than 0.3mBq, which is lower than the detection limit of the radiometric method used for environmental samples. The purified Tc-99m eluate is used as yield tracer for the determination of low levels of Tc-99 in environmental samples. (c) 2007 Elsevier Ltd. All rights reserved.
机译:通过伽马光谱法和液体闪烁计数法测量从商用Mo-99 / Tc-99m发生器获得的Tc-99m示踪剂溶液中Tc-99和杂质放射性核素的浓度。在Tc-99m洗脱液中发现了Mo-99和Ru-103。研究了使用两个额外的氧化铝小柱进行的简单分离,以纯化洗脱液,以获得具有低Tc-99浓度的合适Tc-99m示踪剂。制备的Tc-99m溶液中Tc-99 / Tc-99m的活度比低于15 x 10(-9),高于理论比值小于10 x 10(-9)。讨论了可能的原因。发现加标为20 kBq的Tc-99m示踪剂中的Tc-99小于0.3mBq,这低于用于环境样品的放射法的检测极限。纯化的Tc-99m洗脱液用作产量示踪剂,用于测定环境样品中的低水平Tc-99。 (c)2007 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号