首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Performance analysis of a modified zeotropic mixture (R290/R600) refrigeration cycle with internal subcooler for freezer applications
【24h】

Performance analysis of a modified zeotropic mixture (R290/R600) refrigeration cycle with internal subcooler for freezer applications

机译:具有冷冻室应用的内部过冷器的改良型共沸混合物(R290 / R600)制冷循环的性能分析

获取原文
获取原文并翻译 | 示例
       

摘要

This study presents a modified vapor compression refrigeration cycle (MVRC) using zeotropic mixture R290/R600 for freezers. In the MVRC, an internal subcooler with additional bypass tube is introduced to enhance the overall system performance. Energetic and exergetic analysis methods are introduced to theoretically evaluate the system operating performance, and compared with the performance of the traditional vapor compression refrigeration cycle (TVRC). The results show that the MVRC yields higher refrigeration coefficient of performance (COP), volumetric cooling capacity and exergy efficiency than the TVRC. Under the given condition, the COP, volumetric cooling capacity and exergy efficiency of MVRC could be improved by up to an average of 8.9%, 12.4% and 10.4%. Moreover, COP and exergy efficiency of MVRC increases with the rising bypass coefficient of the refrigerant. The performance characteristics of the proposed novel cycle demonstrate the potential advantages for application in freezer systems. (C) 2016 Elsevier Ltd. All rights reserved.
机译:这项研究提出了一种改良的蒸汽压缩制冷循环(MVRC),该制冷系统使用共沸混合物R290 / R600用于冷冻机。在MVRC中,引入了带有附加旁路管的内部过冷器,以增强整体系统性能。引入能量和能量分析方法来从理论上评估系统的运行性能,并与传统的蒸气压缩制冷循环(TVRC)进行比较。结果表明,MVRC比TVRC具有更高的制冷性能系数(COP),容积制冷量和火用效率。在给定的条件下,MVRC的COP,容积冷却能力和火用效率可平均提高8.9%,12.4%和10.4%。此外,随着制冷剂旁路系数的增加,MVRC的COP和(火用)效率也随之增加。所提出的新型循环的性能特征证明了在冷冻系统中应用的潜在优势。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号