The dynamic characteristics of a medium air-to-water heat pump with multi-circuit evaporator controlled by the thermostatic expansion valve (TEV) under the frosting/defrosting conditions were investigated experimentally. The airflow maldistribution often occurs if the fin-and-tube heat exchangers in a medium heat pump are arranged in V-type or W-type position with the fan at the top. The experimental results show that the airflow maldistribution will result in the intermittent or unceasing hunting during the frosting period, which is not published in public yet. The airflow uniformity causes every circuit to see the different airflow rates. The liquid refrigerant was not evaporated completely in some circuits with the less airflow rate and a little liquid refrigerant flowed out at the outlet, which resulted in less superheat than the necessary MSS (minimum-stable-signal) of the TEV at the outlet of the evaporator. The TEV had the intermittent hunting during the first two-thirds of the frosting period. Afterwards, the combination of the airflow maldistribution and the airflow drop caused by the frost blocking resulted in more liquid refrigerant flowing out of the evaporator. Hence, the TEV had the unceasing hunting during the last one-third of the frosting period. Finally, the operating parameters for both the low-pressure and the high-pressure sides have the intermittent or unceasing hunting during the frosting period, which synchronized with that of the TEV.
机译:实验研究了温控膨胀阀(TEV)控制的多回路蒸发器中空水热泵在结霜/除霜条件下的动态特性。如果将中型热泵中的翅片管式换热器布置在V型或W型位置且风扇在顶部,则经常会发生气流分布不均的情况。实验结果表明,结霜期间气流分布不均会导致断续或不停跳动,目前尚未公开。气流均匀性使每个回路看到不同的气流速率。在某些回路中,液体制冷剂没有完全蒸发,气流速率较小,并且出口处流出的液体制冷剂很少,因此产生的过热度低于TEV出口处所需的TEV的MSS(最小稳定信号)。蒸发器。在结霜期的前三分之二期间,TEV间歇性摆动。此后,气流分布不均和结霜导致的气流下降相结合,导致更多的液态制冷剂从蒸发器中流出。因此,TEV在结霜期的最后三分之一期间不断跳动。最终,低压侧和高压侧的运行参数在结霜期间具有间歇性或不间断的波动,这与TEV的同步。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号